Communication Tests
03/07/03
10-3
DATA TERMINAL
1.
Be sure both the data terminal and printer are ON.
2.
Locate the SELECT button on the printer and make sure it lights.
3.
Press RETURN. (You may have to set up switches and parameters on the terminal). The
system should respond:
sign on
.
4.
Type
GASBOY
and press RETURN.
NOTE: For security reasons,
GASBOY
will not print as you type it.
The system should respond:
Connected to site 1001 on
along with the day, date, and time,
followed by the command prompt (
A
*
or
C
*
). For an Islander, the command prompt is
E
*
.
5.
Type
P DA
and press RETURN. The system prints the date, time, transaction numbers,
sequence number, and version number, followed by the command prompt (
A
*
,
C
*
,
E
*
).
6.
Type
LOG MESS...Testing Okidata Printer
The printer should repeat the typed message plus the date and time.
7.
Type
EX
and press RETURN. The system prints
Sign off
, along with the day, date, and
time. When connected to the port 0, the system goes into the monitor mode.
MODEM
If modem is not supplied by GASBOY, it must be set up using the following parameters:
-
modem hangs up with on/off transmission of DTR
-
auto answer enabled
-
carrier detect present when connection is complete
-
jack select RJ41S RJ455
-
bell compatible with 103/212A modems
-
line error detect disabled
-
result code disabled
NOTE:
This procedure verifies remote polling only. This is not a network test. Consult your
network representative for network testing.
1.
Turn on the site modem and the modem/data terminal device from which the call will
originate.
2.
Set communication program to proper baud rate (2400 default), N, 8, 1 (see the operator's
manual that comes with the modem).
3.
Dial up the CFN site and establish a communication link with the system.
4.
Press RETURN. The system should respond
Sign on
.
5.
Type
GASBOY
and press RETURN
NOTE: For security reasons,
GASBOY
will not print as you type it.
The system should respond:
Connected to site 1001 on
along with the day, date, and time,
followed by the command prompt (
A
*
or
C
*
). For an Islander, the command prompt is
E
*
.
6.
Type
P DA
and press RETURN. The system prints the date, time, transaction numbers,
sequence number, and version number, followed by the command prompt (
A
*
,
C
*
, or
E
*
).
7.
Type
EX
and press RETURN. The system prints
Sign off
when connected to the remote
port, and terminates the communication line.
8.
Hang up the phone.
Содержание CFN Series
Страница 1: ...CFN SERIES SITE CONTROLLER II ISLANDER II START UP MANUAL C01665 GASBOY INTERNATIONAL LLC ...
Страница 2: ......
Страница 8: ...CFN Series System Contents 4 03 07 03 ...
Страница 24: ...CFN Series System 2 12 03 07 03 ...
Страница 25: ...Site Information 03 07 03 2 13 ...
Страница 26: ...CFN Series System 2 14 03 07 03 ...
Страница 38: ...CFN Series System 4 6 03 07 03 ...
Страница 56: ......
Страница 58: ......
Страница 72: ......
Страница 82: ...CFN Series System 9 10 03 07 03 ...
Страница 104: ...CFN Series System 12 12 03 07 03 ...
Страница 108: ...CFN Series System 13 4 03 07 03 ...