Section 5 . Claims

GCT will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling 

warranty statement included with your product and proper return procedures are followed. To request warranty service, 

please provide:

•  The serial number of the defective product

•  A description of the problem

•  A valid shipping address

•  Full Data Logs

To start the process of filing a claim for a product under warranty, please e-mail [email protected] with the 

aforementioned information. Please note that the defective product must be returned to GCT address which is 305 W. FM 

1382, Suite 540, Cedar Hill, TX 75104, with provided prepaid shipping label.

GCT will retain possession of disposable detectors that are returned and found to be beyond their warranty period. This 

includes, but is not limited to, detectors that display EOL (End Of Life) on the screen.

REPAIR OR REPLACEMENT (OR, IN LIMITED CIRCUMSTANCES, REFUND OF THE PURCHASE PRICE) AS PROVIDED UNDER 

THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER. GCT NEITHER ASSUMES NOR AUTHORIZES ANY PERSON 

TO CREATE FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT.

GCT SHALL NOT BE LIABLE TO PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL 

DAMAGES, ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY (INCLUDING BUT NOT LIMITED TO 

ANY IMPLIED WARRANTY OF MERCHANTABILITY).

Содержание Multi Gas Clip

Страница 1: ...Single Gas Clip Plus Single Gas Clip User s Manual G A S C L I P T E C H C O M...

Страница 2: ...n 5 Turning the Detector On 5 Turning the Detector Off 5 Performing a Self test 5 Alarms 7 Detector Maintenance 8 Bump Test Interval bUP 8 O2 Detector Calibration 8 Cleaning 9 Hibernation SGC Plus Onl...

Страница 3: ...ion The CO and H2S versions of both the Single Gas Clip and SGC Plus do not require calibration for the life of the product The detector should be bump tested before each day s use with a known concen...

Страница 4: ...ur l talonnage Les versions CO et H2S du Single Gas Clip et du SGC Plus ne n cessitent pas d talonnage pendant toute la dur e de vie du produit Le d tecteur doit tre test avant chaque utilisation quot...

Страница 5: ...of 15 DETECTOR COMPONENTS ENTRY DESCRIPTION 1 Audible Alarm Port 2 Display 3 Alarm Bar LEDs 4 Maintenance LEDs 5 Power Button 6 Sensor 7 Infrared IR Communication Window 8 Alligator Clip with Safety...

Страница 6: ...play Details The detector utilizes a special high viewing angle LCD that is designed to enhance the screen visibility In the absence of gas it displays life remaining In those cases where gas is prese...

Страница 7: ...and the sensor is tested Below we outlined the most common screen configurations however if the detector has been programmed via the GCT IR Link or has been exposed to gas additional screens may appea...

Страница 8: ...ctor will be reset Note while the value will be cleared on the display the value will be held in the detector s log See the event log section for further details This value can be cleared on the next...

Страница 9: ...life Please discontinue use Alarm Types LOW ALARM Audible alarm One 1 slow beep every second Visual alarm One 1 slow flash every second Vibrating alarm One 1 slow vibration every second HIGH ALARM an...

Страница 10: ...button press to skip the bump test If the SGC is bumped while showing GAS then it will record as a bump test in the event log instead of as an exposure If no gas is applied it will return to the norma...

Страница 11: ...ve the event log by pressing the save event log before hibernating 4 Click on the Hibernate Button acknowledge the event log message 5 Keep in front of the GCT IR Link until the Hibernate OK message i...

Страница 12: ...of logs you want to download a Event Logs Only b Events Partial Data Log last week of data c Events New Data Logs Only All data logs from last time you pulled the logs to current d Full Logs approxim...

Страница 13: ...CALCAP Replacement calibration cap for the Single Gas Clip or the Single Gas Clip Plus Single Gas Clip Dock P N SGC DOCK portable chargeable all in one docking station in a durable portable case for a...

Страница 14: ...ts Newer events replace older events Warranty Full 2 years SGC or 3 years SGC Plus Gas Range Resolution Accuracy T90 Gases H2S 0 100 ppm 0 1 2 ppm 30 s CO 0 300 ppm 1 5 ppm 30 s O 0 30 vol 0 1 0 7 vol...

Страница 15: ...with a damp cloth Intrinsically Safe S curit lntrins que Class I Division 1 Groups A B C and D T4 Ex ia IIC T4 Ga Class I Zone 0 AEx ia IIC T4 Ga 40 C H2S 40 C CO 35 C O Ta 50 C CAN CSA C22 2 No 60079...

Страница 16: ...arranty length of coverage for products sold without an Activate Before Date shall be two 2 years beginning upon the original end user s documented date of purchase or one 1 year from the product s or...

Страница 17: ...aforementioned information Please note that the defective product must be returned to GCT address which is 305 W FM 1382 Suite 540 Cedar Hill TX 75104 with provided prepaid shipping label GCT will ret...

Отзывы: