background image

SGC and SGC Plus User’s Manual

UM SGC v3.0

10 of 15

How to Retrieve Data Logs Using the GCT IR Link

*You must have Microsoft Excel to open Data and/or Event Logs

*Computer System Requirements: Available for Windows© based PCs (Vista, 7, 8.x, 10)

*Browser requirements: Google Chrome, Firefox, Opera or Edge

Set the detector in front of the GCT IR Link with the GCT IR Link Communication Window and the monitor’s Commu-

nication Window lined up approximately 2-3 inches apart.

1.  Open the GCT IR Link Software (downloaded for free from www.gascliptech.com under Resources tab).

2.  Click on Download Logs icon   at the top left corner.

3.  Select Destination Folder (wherever you want to store the logs on your computer).

4.  Select what kind of logs you want to download:

a.  Event Logs Only

b.  Events & Partial Data Log (last week of data)

c.  Events & New Data Logs Only (All data logs from last time you pulled the logs to current)

d.  Full Logs (approximately 2 months)

5.  If a check mark is in the box above where you select what logs you want to download, the logs will automatically 

open in Microsoft Excel once it’s downloaded.

DETECTOR RECORDS (LOGS)

Event Log

 

By default the detector stores the last twenty-five (25) alarm events. The system stores events by first in first out, i.e. the

26th event will replace the first event and so on. This information can be downloaded using the GCT IR Link. For each 

alarm event the detector records the following:

•  The detector serial number

•  Bump Test (Yes or No)

•  Life remaining on the detector  

•  Number of self-tests performed

•  Number of events

•  Alarm Condition (Low, High, or OL)

•  Specific event date and time
•  Peak gas concentration in ppm or %

Содержание Multi Gas Clip

Страница 1: ...Single Gas Clip Plus Single Gas Clip User s Manual G A S C L I P T E C H C O M...

Страница 2: ...n 5 Turning the Detector On 5 Turning the Detector Off 5 Performing a Self test 5 Alarms 7 Detector Maintenance 8 Bump Test Interval bUP 8 O2 Detector Calibration 8 Cleaning 9 Hibernation SGC Plus Onl...

Страница 3: ...ion The CO and H2S versions of both the Single Gas Clip and SGC Plus do not require calibration for the life of the product The detector should be bump tested before each day s use with a known concen...

Страница 4: ...ur l talonnage Les versions CO et H2S du Single Gas Clip et du SGC Plus ne n cessitent pas d talonnage pendant toute la dur e de vie du produit Le d tecteur doit tre test avant chaque utilisation quot...

Страница 5: ...of 15 DETECTOR COMPONENTS ENTRY DESCRIPTION 1 Audible Alarm Port 2 Display 3 Alarm Bar LEDs 4 Maintenance LEDs 5 Power Button 6 Sensor 7 Infrared IR Communication Window 8 Alligator Clip with Safety...

Страница 6: ...play Details The detector utilizes a special high viewing angle LCD that is designed to enhance the screen visibility In the absence of gas it displays life remaining In those cases where gas is prese...

Страница 7: ...and the sensor is tested Below we outlined the most common screen configurations however if the detector has been programmed via the GCT IR Link or has been exposed to gas additional screens may appea...

Страница 8: ...ctor will be reset Note while the value will be cleared on the display the value will be held in the detector s log See the event log section for further details This value can be cleared on the next...

Страница 9: ...life Please discontinue use Alarm Types LOW ALARM Audible alarm One 1 slow beep every second Visual alarm One 1 slow flash every second Vibrating alarm One 1 slow vibration every second HIGH ALARM an...

Страница 10: ...button press to skip the bump test If the SGC is bumped while showing GAS then it will record as a bump test in the event log instead of as an exposure If no gas is applied it will return to the norma...

Страница 11: ...ve the event log by pressing the save event log before hibernating 4 Click on the Hibernate Button acknowledge the event log message 5 Keep in front of the GCT IR Link until the Hibernate OK message i...

Страница 12: ...of logs you want to download a Event Logs Only b Events Partial Data Log last week of data c Events New Data Logs Only All data logs from last time you pulled the logs to current d Full Logs approxim...

Страница 13: ...CALCAP Replacement calibration cap for the Single Gas Clip or the Single Gas Clip Plus Single Gas Clip Dock P N SGC DOCK portable chargeable all in one docking station in a durable portable case for a...

Страница 14: ...ts Newer events replace older events Warranty Full 2 years SGC or 3 years SGC Plus Gas Range Resolution Accuracy T90 Gases H2S 0 100 ppm 0 1 2 ppm 30 s CO 0 300 ppm 1 5 ppm 30 s O 0 30 vol 0 1 0 7 vol...

Страница 15: ...with a damp cloth Intrinsically Safe S curit lntrins que Class I Division 1 Groups A B C and D T4 Ex ia IIC T4 Ga Class I Zone 0 AEx ia IIC T4 Ga 40 C H2S 40 C CO 35 C O Ta 50 C CAN CSA C22 2 No 60079...

Страница 16: ...arranty length of coverage for products sold without an Activate Before Date shall be two 2 years beginning upon the original end user s documented date of purchase or one 1 year from the product s or...

Страница 17: ...aforementioned information Please note that the defective product must be returned to GCT address which is 305 W FM 1382 Suite 540 Cedar Hill TX 75104 with provided prepaid shipping label GCT will ret...

Отзывы: