Summary of Contents for Axiom

Page 1: ......

Page 2: ...11 Detection Modes 12 Fine Normal Large Salt 12 Volume and Threshold Adjustment 13 Tone and Audio Options 14 Target Signal Strength Indicators 15 Backlight Speed Sensitivity 16 Ground Balance Procedur...

Page 3: ...wer the searchcoil to about one half inch 1 25 cm above the ground and scan the coil left and right at approximately 3 feet second 1 meter second The coil must be in motion for target detection This p...

Page 4: ...ngthen lower stem until it snaps into place Adjust upper stem BATTERY CHARGING 12V battery terminal charging with optional cables Charge time 10 hours approx ADJUSTING ARM CUFF Use hexnut wrench store...

Page 5: ...r stem to comfortable length and close stem clamps 2 Wrap cable snugly around stem with first turn of cable over the stem 3 Insert coil connector into back of control box making sure to properly line...

Page 6: ...se Plus Minus buttons are also used to alter detector settings 4 MENU Iron Check Repeatedly press to scroll through menu items then press the Plus or Minus buttons directly above the Menu button to ch...

Page 7: ...es current Sensitivity setting 8 Battery Level Shows status of battery life 25 per segment Recharge battery when one segment remains 9 Speed Select Slow Medium or Fast detection speed see page 17 10 G...

Page 8: ...internal battery it should be charged prior to storage for extended periods and recharged at least once per year It is not necessary to fully discharge the Axiom battery prior to charging In the event...

Page 9: ...with a 3 amp capacity will provide the fastest charge P Battery Information continued Charging From 12V Battery Terminals optional Attach the black negative clip to the negative battery terminal and t...

Page 10: ...tton until the wireless icon is highlighted as indicated in this illustration Press the button to pair the headphones Once paired if the headphone receiver is switched off or moved out of range Axiom...

Page 11: ...beep occurs Frequency Scan Use this function to obtain the quietest operating frequency Audio responses can become erratic at times due to sources of electromagnetic interference EMI Operating near po...

Page 12: ...altwater FINE is typically the preferred mode for most conditions NORMAL Mode Provides very good detection on all size targets NORMAL will be less reactive in highly mineralized soil but will have red...

Page 13: ...response Axiom Threshold is adjustable between 9 and 25 The default setting is 15 It is recommended the Threshold be set to a barely audible level or just below based on hearing ability and surroundin...

Page 14: ...ly to the target s signal strength Large strong signals sound loud and small weak signals sound faint This enhances the ability to judge a target s size shape and depth In addition to enhancing target...

Page 15: ...udio pitch is fixed at either a high or low tone the pitch is not proportional Some users prefer this type of audio for its active coarse response Audio 01 VCO Audio In VCO Audio the target s volume a...

Page 16: ...y You may notice an increase in EMI and noise chatter compared to the SLOW setting but will still provide good depth and sensitivity FAST This setting allows a faster coil swing to search an area more...

Page 17: ...the ground Press and hold the GND BAL button while bouncing the searchcoil from 1 to 6 inches above the ground Continue pumping the coil until the ground response is completely eliminated or becomes a...

Page 18: ...nly pumping the coil up and down above the soil hold down the GND BAL button while combining a verticle pump over the soil with a horizontal scan across the hot rock in a repeating pattern as shown Be...

Page 19: ...ter to changes in ground conditions FAST The ground balance values will track even faster for use in quickly changing ground conditions but this setting may also produce the greatest loss in detection...

Page 20: ...uzz sound that may or may not be flanked by normal tones Non ferrous and or weak targets will produce normal tones or may even be silent but typically won t produce the iron tone buzz Note Iron Check...

Page 21: ...to collapse the Axiom to a very compressed operating length First fully collapse the upper stem Then collapse the lower stem partially leaving at least 10 inches 25 cm of stem exposed This distance he...

Page 22: ...oins etc will produce a high tone followed by a low tone echo Good conductors such as large nuggets copper and silver coins large bronze coins etc should produce a low tone followed by a high tone ech...

Page 23: ...ary Remember that your searchcoil is submersible but your control housing and connectors are not Recharge the detector s battery at least once a year if you are not using it regularly Metal Detecting...

Page 24: ...e Hold the coil perfectly stationary on the ground away from any target a If noise continues then it is likely caused by electrical interference EMI i Perform Frequency Scan ii Reduce sensitivity if n...

Page 25: ...om Click on the Sport Division and then theWarranty Support menu for more details This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...

Page 26: ...justment Audio 00 PWM audio or Audio 01 VCO audio Sensitivity Depth Adjustments 8 Water Weather Resistance Waterproof coil stem Rainproof control box Available Searchcoils 11 x 7 mono coil 11 x 7 DD c...