background image

 

 

 

 

 

 

    GRILLS 

      

 

 

 

MODEL 

MWG-9501 

    MODEL MWGH-9501 
    MODEL MWGF-9501 

MODEL MWGFH-9501 
MODEL MWGL-9501 

    MODEL MWGR-9501 

 

                                 

 

 

           

 OPERATIONS MANUAL 

 

 MANUFACTURED EXCLUSIVELY FOR 

McDONALD'S

 

                      BY  

GARLAND COMMERCIAL INDUSTRIES, INC. 

    185 EAST SOUTH STREET 

       FREELAND, PENNSYLVANIA 18224  
      TOLL FREE:  (800) 446-8367 

 PHONE:  (570) 636-1000 

       FAX:  (570) 636-9874 

    E-mail:  [email protected] 

 

 

NOTE:

 

This manual pertains to both clam grill and flat grill models.  The reader/operator must interpret its contents to applicable needs.  However, 

if there is any question of interpretation of any literature pertaining to Garland grills, please contact our Customer Service Department at 
one of the phone numbers listed above. 

 

 

FOR YOUR SAFETY  

 

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE 

VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY 

OTHER APPLIANCE. 

WARNING: 

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, 

SERVICE OR MAINTENANCE CAN CAUSE PROPERTY 

DAMAGE, INJURY OR DEATH.  READ THE INSTALLATION, 

OPERATING AND MAINTENANCE INSTRUCTIONS 

THOROUGHLY BEFORE INSTALLING OR SERVICING THIS 

EQUIPMENT. 

 
KEEP APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES! 
 
PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE. 
 
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED BY PROFESSIONAL 
PERSONNEL AS SPECIFIED. 
 
ALL BURNER ADJUSTEMENTS AND SETTINGS MUST BE MADE BY A QUALIFIED GAS TECHNICIAN. 

 

NOTE: 

Unit must be installed with no less than six inches (6") clearance from combustible construction at both sides and 
rear. 

 
FOR YOUR SAFETY:  

Post in a prominent location, instructions to be followed in the event the user smells gas.  This information shall be 
obtained by consulting your local gas supplier.
 

 

CAUTION: THIS EQUIPMENT MUST ONLY BE OPERATED UNDER AN APPROVED HOOD SYSTEM 

 

THIS EQUIPMENT “MUST” BE INSTALLED AND COMMISSIONED BY A PROFESSIONAL 
FACTORY TRAINED TECHNICIAN 

         0049 

Part # 1382684 Rev. 4   
CE Configuration                         

Printed in the U.S.A. 

(03/99) 

Содержание MWGH-9501

Страница 1: ...ICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT KEEP APPLIANCE AREA F...

Страница 2: ...L GRILL CONTROLS 16 DESCRIPTION OF GRILL CONTROLS 17 The Master Power Start On Stop Off Switch 17 Indicator Lights 17 Up Arrow Button Two Functions 17 Right Arrow Button Two Functions 17 Program Mode...

Страница 3: ...e 22 To Add Program a Optional Menu Clam 22 To Add Program Optional Menu Flat 23 To Add Program High Limit Grill 24 To Add Program High Limit Platen 24 CALIBRATION 25 CLEANING AND MAINTENANCE 26 AFTER...

Страница 4: ...s or our agents shall not be held liable for any claims of personal injury or consequential damage or loss This warranty gives you specific legal rights and you may have other rights which vary from s...

Страница 5: ...propriate Material Safety Data Sheet s MSDS WARNING After turning the master power switch to the START position the grill will go through an initialization process If the upper platens are in the lowe...

Страница 6: ...AL INSTALLATION Slide release material rod through hemmed end of the release material sheet Hook release material rod on brackets located at the rear of the upper platen Release Material Hook Upper Pl...

Страница 7: ...7 NOTES...

Страница 8: ...T SPECIFICATIONS Gas Type Heat Input kW Setting Pressure Manifold Pressure Flow Rate Natural 18 46 20 25 mbar 8 75mbar 1 96 m3 h Propane 18 88 30 37 50 mbar 25 mbar 1 46 kg h MINIMUM CLEARANCES FOR SE...

Страница 9: ...IFICATIONS Gas Type Heat Input kW Setting Pressure Manifold Pressure Flow Rate Natural 9 23 20 25 mbar 8 75mbar 0 98 m3 h Propane 9 44 30 37 50 mbar 25 mbar 0 73 kg h MINIMUM CLEARANCES FOR SERVICING...

Страница 10: ...UT SPECIFICATIONS Gas Type Heat Input kW Setting Pressure Manifold Pressure Flow Rate Natural 18 46 20 25 mbar 8 75mbar 1 96 m3 h Propane 18 88 30 37 50 mbar 25 mbar 1 46 kg h MINIMUM CLEARANCES FOR S...

Страница 11: ...ype Heat Input kW Setting Pressure Manifold Pressure Flow Rate Natural 18 46 20 25 mbar 8 75mbar 1 96 m3 h Propane 18 88 30 37 50 mbar 25 mbar 1 46 kg h MINIMUM CLEARANCES FOR SERVICING TOP FRONT LEFT...

Страница 12: ...mbar 8 75mbar 1 96 m3 h Propane 18 88 30 37 50 mbar 25 mbar 1 46 kg h MINIMUM CLEARANCES FOR SERVICING TOP FRONT LEFT SIDE RIGHT SIDE REAR mm 600 150 150 150 ELECTRICAL REQUIREMENTS 3N 400V 50Hz kW LO...

Страница 13: ...nifold Pressure Flow Rate Natural 18 46 20 25 mbar 8 75mbar 1 96 m3 h Propane 18 88 30 37 50 mbar 25 mbar 1 46 kg h MINIMUM CLEARANCES FOR SERVICING TOP FRONT LEFT SIDE RIGHT SIDE REAR mm 600 150 150...

Страница 14: ...of clearance between the handle on the front of the upper platen and the lower lip of the ventilation system hood The raised position of each platen is adjusted by raising or lowering the upper of th...

Страница 15: ...This is to be found on the following page in this manual When the burner is correctly adjusted the alternate rating plate decal must be placed over the existing rating plates to reflect the new catego...

Страница 16: ...LIGHTS MENU BUTTON TEMPERATURE PROGRAM FUNCTION BUTTON PROGRAM MODE BUTTON RIGHT ARROW BUTTON UP ARROW BUTTON WHEN PUSHED SIMULTANEOUSLY CLAM MODELS ONLY CANCEL RAISE PLATEN BUTTON STANDBY BUTTON PRO...

Страница 17: ...lay the Remove time Top Temperature Bottom temperature and Gap setting for the menu item displayed Each item will be displayed in the order as stated above After 5 seconds the display will return to t...

Страница 18: ...l lower to the preset gap and the timing will automatically start 3 When the cook cycle times down to five 5 seconds remaining a pre time out alarm will sound to alert the grill operator 4 When the co...

Страница 19: ...the required menu displayed press the UP ARROW button 2 Pressing the UP ARROW button repeatedly will cycle through and display that menu s function time s set temperature s and the gap setting if appl...

Страница 20: ...needed to access them 352 352 9 56 21 9 56 21 352 352 352 352 0 18 7 06 0 18 7 06 6 67 0 6 783 6 67 0 6 783 0 18 0 18 0 18 0 18 0 18 0 18 0 18 0 18 6 7 6 7 6 7 6 7 7 03 7 03 81 7 21 81 7 21 352 8 7 35...

Страница 21: ...button twice to display SYSTEM SETUP 3 PRESS and HOLD the UP ARROW button for ten 10 seconds GAP CALIBRATION will be displayed 4 PRESS the MENU button The hold feature will display OFF 5 HOLD the RIG...

Страница 22: ...dvance the cursor to the right for changing its value 7 PRESS the PROG button to display MENU ITEMS 8 PRESS the RIGHT ARROW button to return to the normal OPERATING MODE To Change Griddle Temperature...

Страница 23: ...right for changing its value Alpha numeric capabilities 24 PRESS the PROG button to display MENU ITEMS 25 PRESS the RIGHT ARROW button to return to the normal OPERATING MODE To Add Program Optional M...

Страница 24: ...PROG button to display MENU ITEMS 28 PRESS the RIGHT ARROW button to return to the normal OPERATING MODE To Add Program High Limit Grill 1 PRESS and HOLD the PROG button for five 5 seconds Display wi...

Страница 25: ...grill plate in the center of the cooking zone Each upper platen has one thermocouple probe in the center Thermocouple Locations FRONT REAR UPPER 14 3 4 7 179mm 375mm 102mm 229mm 5 Select a heat zone d...

Страница 26: ...mp Grill Cleaner HCS and empty the contents into a suitable container One packet cleans a 3ft grill 7 Firmly attach the McD NO SCRATCH Pad to the pad holder 8 Dip the NO SCRATCH Pad into the grill cle...

Страница 27: ...d The controller will turn the heater controlled by the malfunctioning probe OFF If the open probe condition should correct itself the control will return to the IDLE MODE CLAM DID NOT GO DOWN Occurs...

Страница 28: ...E TEST FOR MAIN BURNER FLAME FOR 7 SECONDS FLAME GAS VALVE OPEN MAIN CONTROL CHECKS GAS VALVE STATUS EVERY 12 SECONDS OPEN CONTROL CHECKS FOR TEMPER ATURE INCREASE Y ES UP TO SET TEMPER ATURE TURN OFF...

Страница 29: ...it breakerat service panel is OFF or tripped Reset circuit breaker Call Service Company YES YES NO NO Low internal product temperature s Cook time too short Grill out of calibration Low product qualit...

Страница 30: ...r display reads OFF Call Service Company Reconnect to power supply Reset circuit breaker Press MENU SELECT button NO NO NO YES YES YES Inconsistent or erratic internal product temperatures Carbon buil...

Страница 31: ...Upper platen locking pin engaged Press each controller button Does controller beep Pull locking pin out Allow grill to heat until all LED s are green and display stops flashing NO NO Call Service Com...

Страница 32: ...ower OFF Controller displays TOO HOT then returns to normal operations Current product selected requires a lower temperature than the previous product Allow grill temperature to fall to selected menu...

Страница 33: ...ruption Monitor for repetative error Problem persist YES NO Call for Service Controller displays Faulty Element Shorted Probe Power supply to the grill has been interrupted YES Reset the grill by pres...

Страница 34: ...6 140 F 142 F 144 F 145 F 147 F 149 F 151 F 153 F 154 F 156 F 7 158 F 160 F 162 F 163 F 165 F 167 F 169 F 171 F 172 F 174 F 8 176 F 178 F 180 F 181 F 183 F 185 F 187 F 189 F 190 F 192 F 9 194 F 196 F...

Страница 35: ...35 NOTES...

Страница 36: ...36...

Отзывы: