The unload pressure set at the factory is equal to the compressor’s maximum pressure which cannot
be exceeded.
Setting the discharge pressure:
The pressure indicator light and the lower left segment of the display illuminate when the discharge
pressure is in the programming mode.
NOTICE
Changing the discharge pressure will cause the pressure difference to change.
Compressor automatic timer:
The automatic timer determines how long the compressor runs unloaded before stopping.
The operating hour light illuminates when the unloading time is programmable. This timer is factory
set at 5 minutes.
Automatic start after power failure:
This mode is disabled by setting the value to 0. Other values define the starting delay of the
compressor when power is restored, recommend one (1) minute or longer.
The operating light flashes when automatic starting is programmable.
DANGER
Automatic restarting can cause injury or death. Open, lockout and tagout main
disconnect and any other circuits before servicing the unit.
Condensate removal, open time:
Condensate removal open time is in seconds.
The air filter light illuminates when this can be programmed.
NOTICE
A short condensate removal time and a long interval may cause water to enter
the network. Warm, humid intake air requires longer and more frequent
condensate removal times.
Содержание INTEGRA EFA99F
Страница 15: ...13 8 639 Page 15 Figure 2 2 OUTLINE UNIT PACKAGE 300EFA804 A Ref Drawing ...
Страница 39: ...13 8 639 Page 39 WIRING DIAGRAMS 3 PHASE ...
Страница 40: ...13 8 639 Page 40 WIRING DIAGRAMS 3 PHASE ...
Страница 41: ...13 8 639 Page 41 WIRING DIAGRAMS 3 PHASE ...
Страница 42: ...13 8 639 Page 42 WIRING DIAGRAMS 1 PHASE ...
Страница 43: ...13 8 639 Page 43 WIRING DIAGRAM 1 PHASE ...
Страница 44: ...13 8 639 Page 44 WIRING DIAGRAM 1 PHASE ...