13-8-639 Page 50
WARNING
All materials used in Gardner Denver compressor units are compatible with
AEON 9000SP Lubricating Coolant. Use caution when selecting downstream
components such as air line lubricating bowls, gaskets and valve trim.
AEON 9000SP Synthetic Lubricant is not compatible with low nitrile Buna N or
acrylic paints. AEON 9000SP is compatible with most air system downstream
components.
1. Be sure the unit is completely off and that no air pressure is in the air/oil reservoir.
2. Disconnect, lockout and tagout the power supply to the starter.
3. Thoroughly
drain
system:
•
Drain oil from airend and cooler while hot.
•
Break low point connections and drain oil from pipe runs.
•
Dump oil from filter and reinstall used filter.
4. Fill system with a 50 percent charge of the new lubricant:
•
Start the machine and stay there to observe.
•
Allow the machine to run about five minutes at temperature, or until temperature stabilizes, then
shut down
5. Thoroughly drain machine.
6. Change to a new filter and separator.
7. Fill system with a full charge of the new lubricant.
8. Machine should then be run normally; however, total run time after the initial changeouts should be
50 percent of normal anticipated service life of the new lubricant.
•
Drain all lubricant from system, change filter and separator, and replace with full charge of the
new lubricant.
9. Subsequent
lubricant
changeouts should be at normal intervals. See ”Oil Change Interval”, Figure 5-
3, page 47.
Material Safety Data Sheets (MSDS) are available for all AEON lubricants from your authorized Gardner
Denver distributor or by calling (901) 363-6100.
OIL LEVEL GAUGE
(Figure 5-4, page 51) - The oil level gauge indicates the amount of oil in the air/oil
reservoir. Read oil level only when the unit is shut down and the air/oil mixture has separated. Add oil
only when the oil level is at the bottom of the site glass. Drain oil only when the oil is above the top of the
site glass.
Содержание INTEGRA EFA99F
Страница 15: ...13 8 639 Page 15 Figure 2 2 OUTLINE UNIT PACKAGE 300EFA804 A Ref Drawing ...
Страница 39: ...13 8 639 Page 39 WIRING DIAGRAMS 3 PHASE ...
Страница 40: ...13 8 639 Page 40 WIRING DIAGRAMS 3 PHASE ...
Страница 41: ...13 8 639 Page 41 WIRING DIAGRAMS 3 PHASE ...
Страница 42: ...13 8 639 Page 42 WIRING DIAGRAMS 1 PHASE ...
Страница 43: ...13 8 639 Page 43 WIRING DIAGRAM 1 PHASE ...
Страница 44: ...13 8 639 Page 44 WIRING DIAGRAM 1 PHASE ...