![Gardner Denver INTEGRA EFA99F Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/gardner-denver/integra-efa99f/integra-efa99f_operating-and-service-manual_563798068.webp)
13-8-639 Page 68
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil Carry-Over continued
6.
Foam caused by use of
incorrect oil.
6.
Use Gardner Denver
2000, 4000 or 9000SP
Lubricating Coolant.
7. Inoperative
minimum
pressure valve.
7.
Replace seals in valve.
8.
Operation at elevated
discharge temperatures.
8.
Reduce temperature. See
“High Discharge Air
Temperature”, this
section.
9.
Water condensate in oil.
9.
Check oil reservoir
temperature and if low,
change thermal mixing
valve element to higher
temperature.
Inlet Valve leaks oil after
emergency stop.
1.
Inlet valve seal leaking.
1.
Replace seals in valve.
2.
Control line check valve
failed.
2.
Replace check valve.
DANGER
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters
Содержание INTEGRA EFA99F
Страница 15: ...13 8 639 Page 15 Figure 2 2 OUTLINE UNIT PACKAGE 300EFA804 A Ref Drawing ...
Страница 39: ...13 8 639 Page 39 WIRING DIAGRAMS 3 PHASE ...
Страница 40: ...13 8 639 Page 40 WIRING DIAGRAMS 3 PHASE ...
Страница 41: ...13 8 639 Page 41 WIRING DIAGRAMS 3 PHASE ...
Страница 42: ...13 8 639 Page 42 WIRING DIAGRAMS 1 PHASE ...
Страница 43: ...13 8 639 Page 43 WIRING DIAGRAM 1 PHASE ...