![Gardner Denver INTEGRA EFA99F Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/gardner-denver/integra-efa99f/integra-efa99f_operating-and-service-manual_563798020.webp)
13-8-639 Page 20
WARNING
Failure to properly ground the compressor package could result in injury or
death. Install ground wiring in accordance with the National Electrical Code
and any applicable local codes.
MOTOR LUBRICATION
- Long time satisfactory operation of an electric motor depends in large measure
on proper lubrication of the bearings. The following charts show recommended grease qualities and
regreasing intervals for ball bearing motors. For additional information, refer to the motor manufacturer’s
instructions.
The following procedure should be used in regreasing:
1. Stop the unit.
2. Disconnect, lockout and tagout the unit from the power supply.
3. Remove the relief plug and free hole of hardened grease.
4. Wipe lubrication fitting clean and add grease with a hand-operated grease gun.
5. Leave the relief plug temporarily off. Reconnect unit and run for about 20 minutes to expel the
excess grease.
6. Stop the unit. Replace the relief plug.
7. Restart the unit.
WARNING
Rotating machinery can cause injury or death. Open main disconnect, lockout
and tagout power supply to starter before working on the electric motor.
ELECTRIC MOTOR GREASE RECOMMENDATIONS
Standard
Service
High
Temperature
(104
°
F, 40
°
C)
Worked Penetration ................................................................
265-296
220-240
Grease Viscosity, SSU at 100
°
F ............................................
400-550
475-525
Soap Type ...............................................................................
Lithium
Lithium
N-H Bomb, Minimum Hours for 20 PSI Drop at 210
°
F ..........
750
1000
Bleeding, Maximum Weight % in 500 Hours 212
°
F...............
10
3
Rust Inhibiting .........................................................................
Yes
Yes
Содержание INTEGRA EFA99F
Страница 15: ...13 8 639 Page 15 Figure 2 2 OUTLINE UNIT PACKAGE 300EFA804 A Ref Drawing ...
Страница 39: ...13 8 639 Page 39 WIRING DIAGRAMS 3 PHASE ...
Страница 40: ...13 8 639 Page 40 WIRING DIAGRAMS 3 PHASE ...
Страница 41: ...13 8 639 Page 41 WIRING DIAGRAMS 3 PHASE ...
Страница 42: ...13 8 639 Page 42 WIRING DIAGRAMS 1 PHASE ...
Страница 43: ...13 8 639 Page 43 WIRING DIAGRAM 1 PHASE ...
Страница 44: ...13 8 639 Page 44 WIRING DIAGRAM 1 PHASE ...