3.3.5 Work area examples
B
D
A
C
•
If the charging station is put in a small area
(A), make sure that the distance to the
boundary wire is at a minimum 3 m / 10 ft.
•
If the work area has a passage (B), make
sure that the distance to the boundary wire
is at a minimum 2 m / 6.5 ft. If the passage is
smaller than 2 m / 6.5 ft., install a guide wire
through the passage. Minimum passage
between the boundary wire is 60 cm / 24 in.
•
If the work area has areas which are
connected by small passages (C), you can
change the settings in
Lawn Coverage.
Refer to
•
If the work area includes a secondary area
page 17. Put the product in the secondary
area and select
Secondary area mode.
3.4 Installation of the product
3.4.1 To install the charging station
WARNING: Obey national regulations
about electrical safety.
1. Read and understand the instructions about
the charging station. Refer to
where to put the charging station on page
15.
2. Put the charging station in the selected area.
3. Connect the low-voltage cable to the
charging station.
4. Put the power supply at a minimum height of
30 cm / 12 in.
min 30 cm / 12”
WARNING: Do not put the power
supply at a height where there is a
risk it can be put in water. Do not
put the power supply on the
ground.
WARNING: Do not encapsulate
the power supply. Condensed
water can harm the power supply
and increase the risk of electrical
shock.
5. Connect the power supply cable to a
100-240V outdoor power outlet.
WARNING: Applicable to USA/
Canada. If power supply is
installed outdoors: Risk of Electric
Shock. Install only to a covered
Class A GFCI receptacle (RCD)
that has an enclosure that is
weatherproof with the attachment
plug cap inserted or removed.
1025 - 001 - 23.01.2019
Installation - 19