Further information

Recommendations for twisted pair cables

Both the computer module and the user module provide 

Transmission

 interfaces to 

transmit the following data between the modules.

Transmission: 

keyboard, video, mouse, audio, RS232, USB 2.0 (only 

ARU

 variant)

USB 2.0 Trans.: 

USB 2.0 signals (only 

ARU2

 variant)

The following paragraphs give you recommendations regarding the use of specific 

twisted pair cables.

Transmission of KVM data

The signals 

keyboard, video, mouse, audio, RS232

 and 

USB 2.0

 (only 

ARU 

variant) of the 

DVI-Vision

 system are transmitted via category 5e (or better) twisted pair cables.

Depending on the wire gauge and the type of twisted pair cable, the following dis-

tances can be bridged between computer module and user module.

The following cables achieved the best results during test operation:

up to 140 metres: 

§Kerpen MegaLine G12-150 S/F AWG22

up to 100 metres: 

§G&D K-C5-HR

up to 80 metres:  

§Dätwyler Uninet flex 4P, AWG26, S-STP

NOTE: 

Several segments of a cable connection can be connected with patch panels 

and connection ports.
It is, however, not permitted to connect active components such as network 

switches, hubs or repeaters.

Wire gauge

Cable type

Category

Recommendation

AWG 22

Installation cable

5e, 6 or 7

up to 140 m

AWG 24

Installation cable

5e, 6 or 7

up to 100 m

AWG 26

Patch cable

5e, 6 or 7

up to 80 m

Содержание DVI-Vision-CAT-AR

Страница 1: ...Guntermann Drunck GmbH www gdsys de G D DVI Vision CAT A9100244 1 11 Installation und Bedienung DE EN Installation and Operating Guide...

Страница 2: ...s G D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht bei Li...

Страница 3: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there i...

Страница 4: ...der Standardeinstellungen 18 Tempor re Deaktivierung der Netzfilterregeln 19 Konfiguration 20 bersicht der Funktionen und Standardeinstellungen 20 Bedienung des On Screen Displays am Arbeitsplatz 21 A...

Страница 5: ...Weiterf hrende Informationen 50 Empfehlungen zu den Twisted Pair Kabeln 50 bertragung der KVM Daten Transmission 50 bertragung der USB Daten der ARU2 Variante 51 Unterst tzung beliebiger Grafikaufl s...

Страница 6: ...und alle Spannungsversorgungen am Ger t ab St ndigen Zugang zu den Netzsteckern der Ger te sicherstellen Achten Sie bei der Installation der Ger te darauf dass die Netzstecker der Ger te jederzeit zug...

Страница 7: ...brauchte Batterien d rfen nicht in den Hausm ll geworfen werden Beachten Sie die g ltigen Vorschriften zur Entsorgung elektronischer Produkte CAUTION Risk of explosion if the battery is replaced by an...

Страница 8: ...splatz des Arbeitsplatzmoduls oder am lokalen Arbeitsplatz des Rechnermoduls erfolgen Verf gbare Ger tevarianten Innerhalb der DVI Vision CAT Serie sind verschiedene Varianten verf gbar die die zus tz...

Страница 9: ...es Zubeh r im Lieferumfang der Ger te 2 Stromversorgungskabel PowerCable 2 Standard 1 Videokabel DVI D SL M M 2 1 USB Ger tekabel USB AM BM 2 2 Audio Kabel Audio M M 2 1 serielles Anschlusskabel RS232...

Страница 10: ...t durch andere Ger te beeinflusst wird Um bei Installation mehrerer Ger te bereinander eine gute Luftzirkulation zu erreichen und die gegenseitige thermische Beeinflussung zu vermeiden wird emp fohlen...

Страница 11: ...2 Keyb CPU Verbinden Sie die PS 2 Tastatur Schnittstelle des Rechners mit dieser Schnittstelle Verwenden Sie hierzu die violetten Stecker des Twin PS 2 Kabels Twin PS 2 M M 2 USB CPU Verbinden Sie ein...

Страница 12: ...Verbinden Sie eine USB Schnittstelle des Rechners mit dieser Schnitt stelle Verwenden Sie hierzu das Kabel USB AM BM 2 USB 2 0 Trans Stecken Sie ein als Zubeh r erh ltliches Twisted Pair Kabel der Ka...

Страница 13: ...WEIS Die Tastatur des lokalen Arbeitsplatzes k nnen Sie wahlweise als PS 2 oder USB Ger t anschlie en TIPP Verwenden Sie den Adapter MD6M 2xMD6F A6400043 zum gleichzeitigen Anschluss einer PS 2 Tastat...

Страница 14: ...ltger tekabel ein Red Power An diese Buchse k nnen Sie ein optionales Tischnetzteil anschlie en Hierdurch wird eine zweite redundante Stromversorgung des Ger tes erreicht RS232 Keyb CPU Mouse USB CPU...

Страница 15: ...s siehe USB HID Modus ausw hlen auf Seite 36 wenn Sie ein anderes USB Eingabeger t anschlie en m chten Die Daten des USB Ein gabeger tes werden in diesem Modus unver ndert an das Rechnermodul bertrage...

Страница 16: ...e en Sie hier gegebenenfalls ein Mikrofon an HINWEIS Pro Videokanal der Multi Channel Variante ist je eine DVI VGA Out Schnitt stelle verf gbar Die Ziffern hinter den Schnittstellen Bezeichnungen ordn...

Страница 17: ...oder h her ein Das andere Ende des Kabels ist mit der USB 2 0 Trans Schnittstelle des Rechnermoduls verbin den Stromversorgung herstellen Main Power Stecken Sie ein mitgeliefertes Kaltger tekabel ein...

Страница 18: ...n ab Seite 54 On Screen Display des Arbeitsplatzmoduls Beim Start des Arbeitsplatzmoduls werden Informationen ber den Startvorgang sowie die Firmware Versionen und ID Nummern der verbundenen Module au...

Страница 19: ...e die Zeile Interfaces und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschnitt Interface A folgende Daten HINWEIS Im Auslieferungszustand sind folgende Einstellungen vorausgew hlt IP Adresse de...

Страница 20: ...e Zeile Interfaces und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschnitt Main Network folgende Daten 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Netmask Geben Si...

Страница 21: ...g des Rechners wie der an beiden Arbeitspl tzen freigeschaltet Alternativ zur konkurrierenden Bedienung des Rechners durch die Arbeitspl tze kann die exklusive Bedienung s Seite 16 aktiviert werden Ve...

Страница 22: ...um die in der Zeile angezeigt Operation auszuf hren turn off Steckdose n ausschalten turn on Steckdose n einschalten HINWEIS Nach Aktivierung der exklusiven Bedienung des KVM Extenders an einem Arbeit...

Страница 23: ...er tes und halten Sie diesen gedr ckt 3 Halten Sie den Taster weiterhin gedr ckt und schalten Sie das Ger t ein 4 Sobald die gr ne System LED schnell blinkt lassen Sie die Taste los HINWEIS Um die ver...

Страница 24: ...eln den Zugang auf die Webappli kation k nnen Sie die Netzfilterregeln tempor r deaktivieren um diese anschlie end zu editieren So deaktivieren Sie die eingerichteten Netzfilterregeln tempor r 1 Schal...

Страница 25: ...und Verweise auf die ausf hrlichen Erl uterungen der Funktionen aufgef hrt Funktion Standardeinstellung Seite nderung des Hotkeys Strg 25 nderung der OSD Taste Num 26 On Screen Display mit doppeltem...

Страница 26: ...Aufbau des On Screen Displays Nach der Ausf hrung des Hotkeys wird das OSD auf dem Monitor des Arbeitsplat zes angezeigt Die Men ansichten des On Screen Displays bestehen aus drei Hauptbereichen Funkt...

Страница 27: ...e Informationen aufge f hrt Pfeiltasten Mit den Pfeiltasten Hoch und Runter in einigen Men s auch Links und Rechts bewegen Sie die Positionsmarke zwischen verschiedenen Men eintr gen Eingabetaste Dies...

Страница 28: ...Sicherheitshinweise des Webbrowsers Im KVM Extender ist ein SSL Zertifikat hinterlegt welches dem Webbrowser bzw dem Benutzer erlaubt die Gegenseite zu authentifizieren HINWEIS Grundlegende Informati...

Страница 29: ...Benutzernamen ein Passwort Geben Sie das Passwort Ihres Benutzerkontos ein Sprachauswahl W hlen Sie die Sprache der Benutzeroberfl che Default Standardeinstellung anwenden English Deutsch WICHTIG nde...

Страница 30: ...ie Eingabetaste 3 W hlen Sie die Zeile Hotkey und bet tigen Sie die Eingabetaste 4 W hlen Sie im Abschnitt Modifier mindestens eine der aufgef hrten Hotkey Modifizierertasten durch Markierung des ents...

Страница 31: ...Key durch Bet tigung der F8 Taste eine OSD Taste aus welche gemeinsam mit der bzw den Hotkey Modifizierertaste n den Aufruf des On Screen Displays bewirkt Num Num Taste Standard Pause Pause Taste Ins...

Страница 32: ...te Alt Gr OSD Aufruf mit doppeltem Druck auf die Alt Gr Taste Win OSD Aufruf mit doppeltem Druck auf die Windows Taste Shift OSD Aufruf mit doppeltem Druck auf die Umschalt Taste Print OSD Aufruf mit...

Страница 33: ...Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile System setup und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Hotkey und bet tigen Sie die Eingabetaste 4 W...

Страница 34: ...Sekunden eingestellt werden So ndern Sie die Zeitspanne der Eingabesperre Verwandtes Thema Exklusive Bedienung des KVM Extenders auf Seite 16 OSD 1 Starten Sie das On Screen Display mit dem Hotkey Str...

Страница 35: ...hlen Sie die Berechtigung f r exklusiven Zugriff eines Arbeitsplatzes HINWEIS Nach Aktivierung der exklusiven Bedienung des KVM Extenders an einem Arbeitsplatz blinken an der Tastatur des gesperrten A...

Страница 36: ...ren Arbeitsplatz wird angezeigt sobald die Eingaben des Anwenders am Arbeitsplatz abgeschlossen sind Config Panel 1 Klicken Sie im Strukturbaum auf KVM Extender Alle Extender 2 Doppelklicken Sie das R...

Страница 37: ...Sie in der Zeile Video mode durch Bet tigung der F8 Taste zwischen folgenden Optionen always on Bild immer an Standard switch off Bild bei Aktionen am anderen Arbeitsplatz ausschalten 4 Bet tigen Sie...

Страница 38: ...sf hrliche Informationen hierzu finden Sie im separaten Handbuch zur Webapplikation Config Panel So w hlen Sie den EDID Modus des KVM Extenders HINWEIS Beachten Sie bei der Erstinbetriebnahme sowie be...

Страница 39: ...m den Verbindungsabbruch deutlich zu signalisieren wird das zuletzt empfan gene Bild wahlweise mit einem farbigen Rahmen und oder der Einblendung Frozen und der vergangenen Zeit seit dem Verbindungsab...

Страница 40: ...r vergangenen Zeit seit dem Verbindungsabbruch frame OSD Anzeige des farbigen Rahmens frame und Einblendung des Hinweises Frozen OSD 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nde...

Страница 41: ...blets Sie k nnen den am KVM Extender angeschlossenen Rechner mit einem der unterst tzten Displays oder Tablets bedienen WICHTIG Der Generic HID Modus unterst tzt viele der am Markt erh ltlichen HID Ge...

Страница 42: ...LK463 kom patible Tastatur anschlie en Die Anordnung der 108 Tasten solcher Tastaturen ent spricht dem OpenVMS Tastaturlayout Ein spezieller USB Tastaturmodus gew hrleistet die bermittlung der Bet tig...

Страница 43: ...ID mode und bet tigen Sie die F8 Taste zur Aus wahl einer Option s oben 4 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Config Panel 1 Klicken Sie im Strukturbaum auf KVM Ext...

Страница 44: ...Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Eingabetaste falls Sie die Unterst tzung einer Spezialtastatur f r den entfernten Arbeitsplatz am CON Modul einstell...

Страница 45: ...de Set 3 empfehlenswert Config Panel 1 Klicken Sie im Strukturbaum auf KVM Extender Alle Extender 2 Doppelklicken Sie das Rechnermodul des zu konfigurierenden KVM Extenders 3 Klicken Sie auf den Reite...

Страница 46: ...er durchgef hrten nderungen Die Tastatur wird nach dem erneuten Einschalten initialisiert und das ausgew hlte Scancode Set angewendet Config Panel 1 Klicken Sie im Strukturbaum auf KVM Extender Alle E...

Страница 47: ...Zeile Console setup und bet tigen Sie die Eingabetaste 3 W hlen Sie in der Zeile Keyboard required durch Bet tigung der F8 Taste zwischen folgenden Optionen no Startvorgang bei Fehlen der Tastatur for...

Страница 48: ...ie den Bildschirmschoner des lokalen Arbeitsplatzes am CPU Modul einstellen m chten 3 Geben Sie in der Zeile Screensaver min die Wartezeit 1 bis 999 Minuten des Bildschirmschoners ein Der Wert 0 deakt...

Страница 49: ...n Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Eingabetaste 3 W hlen Sie in der Zeile OSD key layout durch Bet tigung der F8 Taste zwi schen folg...

Страница 50: ...uls mit dem local hotkey Standard Alt Num falls Sie nur die lokalen Einstellungen des Arbeits platzmodul zur cksetzen m chten 2 W hlen Sie die Zeile System setup entferntes OSD bzw Console utility lok...

Страница 51: ...turquoise hellt rkis white wei OSD 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile...

Страница 52: ...e Personal Profile und bet tigen Sie die Eingabetaste 4 W hlen Sie in der Zeile Display durch Bet tigung der F8 Taste zwischen folgenden Optionen Aus Informationseinblendung ausschalten Tempor r tempo...

Страница 53: ...ch Bet tigung der F8 Taste zwi schen folgenden Optionen high hohes Durchscheinen des Bildschirminhalts average mittleres Durchscheinen des Bildschirminhalts Standard low leichtes Durchscheinen des Bil...

Страница 54: ...die Eingabetaste An der aktuellen Position der Informationsein blendung erscheint das rechts abgebildete Men 5 Verwenden Sie die Pfeiltasten oder die Maus um das Men an die gew nschte Position zu vers...

Страница 55: ...lgt ber Twisted Pair Kabel der Kategorie 5e oder h her Abh ngig von der Drahtst rke und des Kabeltyps der Twisted Pair Verkabelung k n nen folgende Entfernungen zwischen dem Rechner und dem Arbeitspla...

Страница 56: ...nd somit Aufl sungen zwischen 640 480 Bildpunkten bei 60 Hz und 1600 1200 Bildpunkten bei 60 Hz m glich 1920 1200 Bildpunkte bei 60 Hz werden nach VESA CVT RB bertragen Innerhalb der in den technische...

Страница 57: ...lossenen Monitors oder die Werksvorgabe des KVM Extenders zu Verf gung blicherweise werden die DDC Informationen des Monitors unver ndert an den Rech ner weitergeleitet Stellt der KVM Extender aber fe...

Страница 58: ...rechenden Pins auf Arbeitsplatzmodul Rechnermodul RS232 Stecker RS232 Buchse Pin Nr Leitung Arbeitsplatz modul Rechner modul 1 DCD Data Carrier Detect Eingang Ausgang 2 RxD Receive Data Eingang Ausgan...

Страница 59: ...ausgeschaltet oder die Verbindung mit dem Stromnetz nicht hergestellt Status Trans an Verbindung zur Gegenstelle hergestellt aus Verbindung zur Gegenstelle nicht hergestellt System an Ger t betriebsbe...

Страница 60: ...mit Gegenstelle hergestellt blinkt Verbindung zur Gegenstelle hergestellt aus Verbindung zur Gegenstelle nicht hergestellt gr n an An Gegenstelle angemeldet aus An Gegenstelle nicht angemeldet USB 2...

Страница 61: ...schaften PS 2 Tastatur Maus 2 PS 2 Buchse USB Tastatur Maus 2 USB A Buchse Generic HID 1 USB A Buchse Audio 3 5 mm Klinkenbuchse Speaker 3 5 mm Klinkenbuchse Micro In USB 2 0 Variante ARU 2 USB A Buch...

Страница 62: ...hrten Inter laced Formate werden unterst tzt Pixelrate 25 MHz bis 165 MHz Vertikalfrequenz 24 Hz bis 120 Hz Horizontalfrequenz 25 kHz bis 130 kHz USB 2 0 Full Speed Variante ARU Spezifikation USB 2 0...

Страница 63: ...nsionen B H T Varianten AR und ARU 210 44 210 mm Desktop 19 1 HE 210 mm Rackmount Variante ARU2 270 44 210 mm Desktop 19 1 HE 210 mm Rackmount Einsatzumgebung Temperatur 5 bis 45 C Luftfeuchte 80 nich...

Страница 64: ...5 Buchse USB 2 0 Variante ARU2 1 RJ45 Buchse Geh use Material Aluminium eloxiert Dimensionen B H T 270 44 210 mm Einsatzumgebung Temperatur 5 bis 45 C Luftfeuchte 80 nicht kondensierend DVI VISION CAT...

Страница 65: ...te ARU2 1 RJ45 Buchse Geh use Material Aluminium eloxiert Dimensionen B H T 435 44 210 mm Einsatzumgebung Temperatur 5 bis 45 C Luftfeuchte 80 nicht kondensierend DVI VISION CAT MC3 CON Schnittstellen...

Страница 66: ...RU2 1 RJ45 Buchse Geh use Material Aluminium eloxiert Dimensionen B H T 435 44 210 mm Einsatzumgebung Temperatur 5 bis 45 C Luftfeuchte 80 nicht kondensierend DVI VISION CAT MC4 CON Schnittstellen f r...

Страница 67: ...60 50Hz 0 4 0 2A 17 9 W MC2 ARU CON 100 240V 60 50Hz 0 6 0 3A 32 4 W MC2 ARU2 CPU 100 240V 60 50Hz 0 4 0 2A 19 4 W MC2 ARU2 CON 100 240V 60 50Hz 0 6 0 3A 33 6 W MC3 AR CPU 100 240V 60 50Hz 0 5 0 3A 3...

Страница 68: ...AR CON 12VDC 1 5A 16 9 W MC2 ARU CPU 12VDC 1 4A 15 8 W MC2 ARU CON 12VDC 2 5A 27 9 W MC2 ARU2 CPU 12VDC 1 5A 16 7 W MC2 ARU2 CON 12VDC 2 6A 28 9 W MC3 AR CPU 12VDC 2 3A 25 9 W MC3 AR CON 12VDC 2 4A 27...

Страница 69: ...Deutsch...

Страница 70: ...ll not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Have bee...

Страница 71: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there i...

Страница 72: ...ng the default settings 19 Temporarily deactivating the netfilter rules 20 Configuration 21 Overview of functions and default settings 21 Operating the on screen display at the console 22 Showing the...

Страница 73: ...ransparency of the on screen display 47 Changing the position of the information dispaly 48 Changing the position of the on screen display 48 Further information 49 Recommendations for twisted pair ca...

Страница 74: ...ice has been disconnected from all power sources Disconnect all power plugs and all power supplies of the device Ensure constant access to the power plugs During the installation of the devices ensure...

Страница 75: ...ot dispose of batteries in municipal waste Check local regulations for the disposal of electronic products ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Mettre au...

Страница 76: ...sole of the user module or at the local console of the computer module Available variants The DVI Vision CAT series provides further variants that additionally enable the trans mission of USB 2 0 sign...

Страница 77: ...ge contents include the following accessories 2 power cable PowerCable 2 Standard 1 video cable DVI D SL M M 2 1 USB device cable USB AM BM 2 2 audio cable Audio M M 2 1 serial connection cable RS232...

Страница 78: ...mit must not be influenced by other devices When installing the devices make sure to only place a maximum of three devices directly on top of each other This way a good circulation of air is provided...

Страница 79: ...terface Keyb CPU Use the green plug of the twin PS 2 cable Twin PS 2 M M 2 to connect the computer s PS 2 keyboard interface to this interface USB CPU Use the USB AM BM 2 cable to connect one of the c...

Страница 80: ...e of the computer s USB interfaces to this interface USB 2 0 Trans Plug a category 5e or better twisted pair cable which is available as accessory into this interface Connect the other end of the cabl...

Страница 81: ...connect the VGA cable of the monitor to the adapter NOTE The keyboard of the local console can either be a PS 2 or a USB device ADVICE Use the adapter MD6M 2xMD6F A6400043 to use a PS 2 keyboard and a...

Страница 82: ...e Red Power To provide a second redundant power supply connect a portable power pack to this interface NOTE One Transmission interface is available for every video channel of multi channel variants Th...

Страница 83: ...e see Selecting the USB HID mode on page 35 if you want to connect another USB input device In this mode any data of the USB input device is not altered when transmitted to the computer module Mouse C...

Страница 84: ...Speaker Connect the speakers or another audio output device NOTE One DVI VGA Out interface is available for every video channel of multi channel variants The number behind the name of the interface as...

Страница 85: ...g a category 5e or better twisted pair cable which is available as accessory into this interface of the ARU2 variant Connect the other end of the cable to the USB 2 0 Trans interface of the computer m...

Страница 86: ...r Insert one of the supplied IEC cables here Red Power To provide a second redundant power supply connect a portable power pack to this interface RS232 DVI VGA Out Mouse Keyb USB 2 0 Devices Micro In...

Страница 87: ...see the chapter Status LEDs on page 53 ff On screen display of the user module When starting the user module information about the starting process as well as the firmware versions and IDs of the conn...

Страница 88: ...terfaces and press Enter 4 Enter the following data under Interface A NOTE In the default settings the following settings are preselected IP address of Network interface A address is obtained via DHCP...

Страница 89: ...ter 3 Select the entry Interfaces and press Enter 4 Enter the following data under Main Network 5 Press F2 to save your settings Netmask Enter the netmask of the network The operational mode DHCP does...

Страница 90: ...page 30 Changing the video mode of consoles on page 32 Operating the KVM extender exclusively Activate the right for permanent access to operate the KVM extender exclusively with one console If this f...

Страница 91: ...Enter to carry out one of the following options turn off turn power outlet s off turn on turn power outlet s on ADVICE In the standard configuration of the KVM extender the computer s video signal is...

Страница 92: ...ce 3 Keep the button pressed and switch on the device 4 Release the button as soon as the green Switch LED is fast blinking NOTE As protection against pressing the button accidentally it is located be...

Страница 93: ...filter rules If the currently adjusted netfilter rules prevent the access to the web application they can be can temporarily deactivated in order to be edited How to temporarily deactivate the netfilt...

Страница 94: ...and references to detailed descrip tions of the functions Function Default setting Page Changing hotkeys Ctrl 26 Changing the OSD key Num 27 Opening the on screen display via double keypress turned o...

Страница 95: ...of the on screen display After pressing the hotkeys the OSD is displayed on the console monitor The on screen display consists of three parts Function Default setting Page Changing the colour of the...

Страница 96: ...st important keys to operate the cur rently displayed menu and further information if available Arrow keys Press the arrow keys Up and Down in some menus also Left and Right to move the cursor between...

Страница 97: ...nload Config Panel Security advice for web browsers The KVM extender stores an SSL certificate which enables the user or the web browser to authenticate the opposite site NOTE The separate manual prov...

Страница 98: ...Enter your username Password Enter your user account password Select language Select the language for the user interface Default apply default setting English German IMPORTANT Change the default pass...

Страница 99: ...screen display 2 Select the row System setup and press Enter 3 Select the row Hotkey and press Enter 4 Under Modifier select at least one of the listed hotkey modifiers by selecting the box with the a...

Страница 100: ...select an OSD key Now you can open the OSD when pressing the OSD key together with the hotkey modifier s Num Num key default Pause Pause key Insert Insert key Delete Delete key Home Home key End End k...

Страница 101: ...e Alt key twice Alt Gr OSD is opened by pressing the Alt Gr key twice Win OSD is opened by pressing the Windows key twice Shift OSD is opened by pressing the Shift key twice Print OSD is opened by pre...

Страница 102: ...1 Press Ctrl Num default to open the on screen display 2 Select the row System setup and press Enter 3 Select the row Hotkey and press Enter 4 Under Exclusive key press F8 to select on of the followi...

Страница 103: ...ed time span of the auto matic input lock default 1 second the default settings of the KVM extender permit the other console to operate the extender If the function right for exclusive console access...

Страница 104: ...ct the row Console setup and press Enter if you want to adjust the right for the remote console at the CON module Select the row Local console setup and press Enter if you want to adjust the right for...

Страница 105: ...nter if you want to adjust the video mode for the remote console at the CON module Select the row Local console setup and press Enter if you want to adjust the video mode for the local console at the...

Страница 106: ...e EDID mode of KVM extenders NOTE For initial operation and when connecting another monitor please follow the activation sequence recommended on page 14 OSD 1 Press Ctrl Num default to open the on scr...

Страница 107: ...n interrupted How to configure the Freeze mode OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter The Freeze mode is adjusted separately for each...

Страница 108: ...eneral The Freeze mode is adjusted separately for each video channel of the user module The following options can be adjusted separately for each video channel of multi channel devices 4 Under Freeze...

Страница 109: ...SETTING PC keyboard with default keyboard layout PC default PC keyboard with additional multimedia keys Multimedia Apple keyboard with numeric keypad A1243 Apple A1243 Sun keyboard German keyboard la...

Страница 110: ...er a special key of this key board pressed this action is transmitted to the target computer How to select a USB HID mode INPUT DEVICE SETTING Contour ShuttlePRO v2 Contour SP2 INPUT DEVICE SETTING LK...

Страница 111: ...be performed by using the hot keys listed below IMPORTANT You can use the emulation of Solaris Shortcut Keys only in the USB modes SUN DE and SUN US HOTKEYS SOLARIS SHORTCUT KEY OF SUN KEYBOARDS Ctrl...

Страница 112: ...te console at the CON module Select the row Local console setup and press Enter if you want to adjust the support of a special keyboard for the local console at the CPU module 3 Under Enh keyboard pre...

Страница 113: ...u turn the KVM extender on again the keyboard is initialised and the selected scancode set is applied Config Panel 1 Click on KVM Extenders All Extenders on the directory tree 2 Double click the compu...

Страница 114: ...on screen display 2 Select the row Console setup and press Enter 3 Under Keyboard required press F8 to select one of the following options no continue starting process without a keyboard default yes i...

Страница 115: ...and press Enter if you want to adjust the screensaver of the local console at the CPU module 3 Under Screensaver min enter a waiting period 1 to 999 minutes for the screensaver Entering the value 0 di...

Страница 116: ...um default to open the on screen display 2 Select the row Console setup and press Enter 3 Under OSD key layout press F8 to select one of the following options German English US English UK French Spani...

Страница 117: ...he extender system Open the local OSD of the user module by pressing the local hotkey default Alt Num if you want to reset the local settings of the user module 2 Select the row System setup remote OS...

Страница 118: ...rquoise silver yellow blue fuchsia light turquoise white OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter 3 Select the row Personal Pprofile an...

Страница 119: ...onal Profile and press Enter 4 Under Display press F8 to select between the following options Off information display is turned off Temporary information display is shown temporarily for 5 seconds def...

Страница 120: ...D transparency press F8 to select on of the following options high high transparency of the screen content average average transparency of the screen content default low low transparency of the screen...

Страница 121: ...p and press Enter 3 Select the row Personal Pprofile and press Enter 4 Select the row Set display position and press Enter The message on the right is shown at the current position of the information...

Страница 122: ...nsmitted via category 5e or better twisted pair cables Depending on the wire gauge and the type of twisted pair cable the following dis tances can be bridged between computer module and user module Th...

Страница 123: ...d 1600 1200 pixels at 60 Hz are possible for the common timing standards by VESA DMT and VESA SMT 1920 1200 pixels at 60 Hz is transmitted according to VESA CVT RB As stated in the technical data see...

Страница 124: ...of the most recently connected monitor or a default data block are provided in the KVM extender The monitor s DDC information is usually transmitted one to one to the computer Should the KVM extender...

Страница 125: ...e assigned to the according pins User module Computer module RS232 plug RS232 socket Pin no Line User module Computer module 1 DCD Data Carrier Detect Input Output 2 RxD Receive Data Input Output 3 Tx...

Страница 126: ...network could not be established Status Trans on The connection to the remote station has been established off The connection to the remote station could not be established System on Device is ready f...

Страница 127: ...ablished blinking Connection to remote station has been estab lished off Connection to remote station has not been estab lished green on Logged on at remote station off Not logged on at remote station...

Страница 128: ...rd mouse 2 PS 2 socket USB keyboard mouse 2 USB A socket Generic HID 1 USB A socket Audio 3 5 mm jack plug Speaker 3 5 mm jack plug Micro In USB 2 0 Variant ARU 2 USB A socket USB 2 0 Variant ARU2 2 U...

Страница 129: ...sted Interlace formats are supported Pixel rate 25 MHz to 165 MHz Vertical frequency 24 Hz to 120 Hz Horizontal frequency 25 kHz to 130 kHz USB 2 0 full speed ARU variant Specification USB 2 0 Transmi...

Страница 130: ...and ARU variants 210 44 210 mm Desktop 19 1 U 210 mm Rackmount ARU2 variant 270 44 210 mm Desktop 19 1 U 210 mm Rackmount Operating environment Temperature 5 to 45 C Air humidity 80 non condensing DVI...

Страница 131: ...2 0 ARU2 variant 1 RJ 45 socket Casing Material anodised aluminium Dimensions W H D 270 44 210 mm Operating environment Temperature 5 to 45 C Air humidity 80 non condensing DVI VISION CAT MC2 CON Int...

Страница 132: ...socket Casing Material anodised aluminium Dimensions W H D 435 44 210 mm Operating environment Temperature 5 to 45 C Air humidity 80 non condensing DVI VISION CAT MC3 CON Interfaces for remote console...

Страница 133: ...5 socket Casing Material anodised aluminium Dimensions W H D 435 44 210 mm Operating environment Temperature 5 to 45 C Air humidity 80 non condensing DVI VISION CAT MC4 CON Interfaces for remote conso...

Страница 134: ...50Hz 0 4 0 2A 17 9 W MC2 ARU CON 100 240V 60 50Hz 0 6 0 3A 32 4 W MC2 ARU2 CPU 100 240V 60 50Hz 0 4 0 2A 19 4 W MC2 ARU2 CON 100 240V 60 50Hz 0 6 0 3A 33 6 W MC3 AR CPU 100 240V 60 50Hz 0 5 0 3A 30 1...

Страница 135: ...MC2 AR CON 12VDC 1 5A 16 9 W MC2 ARU CPU 12VDC 1 4A 15 8 W MC2 ARU CON 12VDC 2 5A 27 9 W MC2 ARU2 CPU 12VDC 1 5A 16 7 W MC2 ARU2 CON 12VDC 2 6A 28 9 W MC3 AR CPU 12VDC 2 3A 25 9 W MC3 AR CON 12VDC 2 4...

Страница 136: ......

Страница 137: ...English...

Страница 138: ......

Страница 139: ...English...

Страница 140: ...re Leimbach 9 57074 Siegen Germany http www gdsys de sales gdsys de Das Handbuch wird fortlaufend aktualisiert und im Internet ver ffentlicht The manual is constantly updated and available on our webs...

Отзывы: