6.5 REGUL ATING THE WATER
PUMP FLOW RATE
Authorised personnel only
Note
The pump flow rate must have
a nominal pressure of 9 bar for
the standard version, or 12 bar
for the DFC version.
- Access the water pump by removing the LH
side panel 6.3.2.
- Loosen the locking nut (1).
- Regulate the flow rate by adjusting the screw
(2).
- When you have finished, replace the LH side
panel.
2
1
6.6 REGUL ATING THE PRE-
INFUSION PRESSURE
Remove the protective covers and tighten or
loosen the screws of the pressure regulators
to increase or reduce the pressure of each
espresso dispensing unit during the pre-infusion
phase.
ENG
72
GENERAL INFORMATION