ALARM
CAUSE
SOLUTION
During dispensing, if the water
softener filter litre counter
reaches the value set in the
Technical menu, a specific
alarm symbol appears at the
bottom right.
To eliminate the alarm, press
and hold the relative icon; the
warning triangle will disappear
and the filter litre counter will
be reset (at the value set in the
Technical menu).
During dispensing, if the
volumetric counter does not
read the impulses correctly, a
specific alarm symbol appears
at the bottom right.
- Check the connection wiring
between the volumetric
counter and the machine
board
- Potential volumetric counter
fault: check and replace
- Potential machine board
fault: check and replace
When the steam boiler
temperature probe is
disconnected (circuit open),
alarm AL3 appears on every
unit.
- Check the connection wiring
between the steam boiler
temperature probe and the
machine board
- Potential steam boiler
temperature probe fault:
check and replace
- Potential machine board
fault: check and replace.
ENG
68
GENERAL INFORMATION
Содержание La Reale
Страница 1: ...INSTALLATION AND USE ...
Страница 6: ...ENG IV CONTENTS ...
Страница 14: ...ENG 8 GENERAL INFORMATION ...
Страница 22: ...ENG 16 GENERAL INFORMATION ...
Страница 25: ...10 A B C 11 7 5 3 D 9 1 8 2 4 6 15 17 A 16 18 19 20 21 B 13 12 D C 14 12 ENG LA REALE GENERAL INFORMATION 19 ...
Страница 29: ...14 3 5 2 10 15 4 6 10 13 11 13 1 8 12 9 7 12 4 A 4 B ENG LA REALE GENERAL INFORMATION 23 ...
Страница 80: ...ENG 74 GENERAL INFORMATION ...
Страница 82: ...ENG 76 GENERAL INFORMATION ...
Страница 83: ...LA REALE ELECTRIC AND HYDRAULIC DIAGRAMS 8 ...
Страница 86: ...ENG 7 PURPLE 7 PURPLE 6 6 6 0 0 0 0 0 0 0 0 0 80 DIAGRAMS ...