ALARM
CAUSE
SOLUTION
Menu 1 - in the event of
synchronisation problems in the
machine software, a general
deactivation alarm appears.
- Switch the machine off, and
then back on again
- Make a factory pre-set in the
Technical menu (contact an
authorised Gaggia Milano
Aftersales Service for the
relative password)
- If possible, try to reload the
software on the machine
board
- Potential machine board
fault: check and replace
Menu 1 - when the heating
of the steam boiler is not
completed within the time limit
set in the software, alarm AL5
appears on every unit.
- Potential steam boiler
heating element fault: check
and replace
- Potential steam boiler safety
thermostat fault: check and
replace
- Potential wiring fault on
steam boiler heating
element: check and replace
- Potential solid state relay
fault: check and replace
- Potential machine board
fault: check and replace
Caution
If alarm AL1, AL2 or AL3 is activated, not only is the info given on the displays
concerned but all the dispensing buttons also start flashing.
ENG
LA REALE
GENERAL INFORMATION
71
Содержание La Reale
Страница 1: ...INSTALLATION AND USE ...
Страница 6: ...ENG IV CONTENTS ...
Страница 14: ...ENG 8 GENERAL INFORMATION ...
Страница 22: ...ENG 16 GENERAL INFORMATION ...
Страница 25: ...10 A B C 11 7 5 3 D 9 1 8 2 4 6 15 17 A 16 18 19 20 21 B 13 12 D C 14 12 ENG LA REALE GENERAL INFORMATION 19 ...
Страница 29: ...14 3 5 2 10 15 4 6 10 13 11 13 1 8 12 9 7 12 4 A 4 B ENG LA REALE GENERAL INFORMATION 23 ...
Страница 80: ...ENG 74 GENERAL INFORMATION ...
Страница 82: ...ENG 76 GENERAL INFORMATION ...
Страница 83: ...LA REALE ELECTRIC AND HYDRAULIC DIAGRAMS 8 ...
Страница 86: ...ENG 7 PURPLE 7 PURPLE 6 6 6 0 0 0 0 0 0 0 0 0 80 DIAGRAMS ...