P a g e
|
20
Figure 13 Alternate system configuration using DynoBond™ clips in place of ground wire
Alternatively, the system can be gounded using only DynoBond™ clips and omitting a traditional ground
wire. For full instructions including how to use a DynoBond™ clip to ground the system, refer to the full
Dynobond™ install manual (DynoRaxx document number 070919).
Notes
The grounding hardware for the Adjustable Foot Assembly (
Figure 10
) can be reused up to 3 times.
The grounding screws for the Adjustable Feet and MLPE bracket (
Figure 9
) are single-time use
only.
The DynoBond™ clips (Figure 11) are single-time use only.
No more than two 10-14 AWG wires can be used in the Weeb® Grounding Lug (
Figure 12
). See
manufacturer’s instructions.
Systems that do not use an MLPE (i.e. use a string inverter instead) must still install the MLPE
bracket and WEEB® Grounding Lug for proper system grounding.
Use only UL-approved methods for splicing the solid copper ground wire
76
"
DynoBond
™
Jumper
Bare Solid
Copper Wire