G.Weike Laser
Profession Laser Manufacturer more than 15 Years.
33
Chapter 5 Testing and operation of the machine
5.1Summarize and operation guide
Boot steps Turn on the power---Open water cooling machine---Open the
emergency stop button---Turn on the laser source---Turn on the software---Back
to the origin---Selective cutting gas---standardization---adjust the light---Drawing
set cutting parameters---Go frame--- Cutting
1.Check equipment as a whole: before electricity mainly to check the
machine's moving parts track route and workbench without exception.
2.An external device to start:
A). Start the total power supply: the total power switch, voltage equipment.
When the light is in this position marked by No.1 arrowhead on Picture 5-1,turn
on the total power switch according to the direction of No.2 on Picture 5-1
arrowhead
Picture 5-1
B) Cold water machine start: heck whether the state is normal, water supply is
normal, waterways without slack phenomenon More details please refer chapter
4.2.Please check water after electricity, observe whether there is leakage
phenomenon, and water pressure the direction of flown water-cooled machine by
its "outlet" --filter -- fiber and cutting head -- water cooling machine "inlet.
C)Open the machine and computer host.
Picture 5-2
Picture 5-3
Picture 5-4 computer host
Содержание LF1390
Страница 1: ......
Страница 2: ...G Weike Laser Profession Laser Manufacturer more than 15 Years ...
Страница 31: ...G Weike Laser Profession Laser Manufacturer more than 15 Years 24 Picture 4 11 Picture 4 1 ...
Страница 44: ...G Weike Laser Profession Laser Manufacturer more than 15 Years 37 Picture 5 10 Picture 5 11 Picture 5 12 ...