7.4 Function with electromechanical locks (‘EK’)
7.4.1 Short-time OPEN (engaging the lever handle)
If a potential-free contact connected to terminals 93 / V4 is actuated with
the door closed, SECURE
connect
200F receives the signal to engage the
lever handle.
If the door remains closed, the lever handle will be disengaged again
after 20 s.
If the door is opened, the lever handle will be disengaged again after 3 s.
If a potential-free contact connected to terminals 93 / V4 is actuated
permanently, the lever handle remains engaged remains for the duration
of the signal (see above).
If the door is opened, the lever handle will be disengaged again after 3 s.
If the door is closed again, the lever handle will be re-engaged.
7.4.2 Permanent OPEN (unlocking)
If a potential-free contact (gating pulse) connected to terminals 91 / V4 is
actuated with the door closed, SECURE
connect
200F receives the signal to
engage the lever handle.
If the door remains closed, the lever handle will remain engaged.
If the door is opened, the lever handle will be disengaged again after 3 s
If the door is closed again, the lever handle will be re-engaged.
7.4.3 Door closing (disengaging the lever handle)
If a potential-free contact connected to terminals 92 / V4 is actuated with
the door closed, SECURE
connect
200F receives the signal to disengage the
lever handle.