54
Power and data transmission unit
Mounting und operating instructions
SECUREconnect 200
12.2013 | 15887EE | Printed in Germany
EN
7.2 LED signalling
The LED indication of SECURE
connect
200 is an important means during
start-up or when it comes to trouble shooting. It provides information on
the different status of the device.
7.2.1 LED indication on SECURE
connect
200R
LED green / LED red
0.5 Hz flashing alternately
Normal status, not paired, no
communication with other devices linked
to the BKS-NET bus
LED green / LED red
1 Hz flashing alternately
Normal status, not paired, communication
with at least one device linked to the BKS-
NET bus
LED green
0.5 Hz flashing
Normal status, paired, no communication
with other devices linked to the BKS-NET
bus
LED green
1 Hz flashing
Normal status, paired, communication
with at least one device linked to the BKS-
NET bus
LED red
2 Hz flashing
Temperature too high
LED red
5 Hz flashing
Trouble: Short circuit
Display with door open and closed.
7.2.2 LED indication on SECURE
connect
200F
LED green
1 Hz flashing
Normal status, not paired
LED green
0.5 Hz flashing
Normal status, paired
LED green
off
Power supply between SECURE
connect
200R
and
200F
interrupted for a longer period of
time
LED green
5 Hz flashing
Trouble:
Short circuit, switch-off, capacitors....
Display with door closed, and up to 15 s after door opening