2. WIRING
7
2.2
Processor Unit
2.2.1
Power cable and grounding
Use either the DPYC-1.5 or DPYC-2.5 cable, according to the cable length. This unit
should be grounded to prevent mutual interference. Connect a copper strap (local sup-
ply) between this unit and the ship’s ground. The length of the ground strap should be
as short as possible.
1. Fabricate the JIS cable (see the Appendix for equivalent cables if not available lo-
cally) as shown below.
2. Unfasten 14 binding screws to remove the cover from the processor unit.
Location of the connectors in the processor unit
Monitor cable
LAN cable
LAN cable
USB cable
Tankenmaru
system
Temperature
sensor
Power cable
Control cable
Transducer cable
TD/ID transducer
cable
Net sonde
signal cable
Satellite Compass
Interface unit
NMEA1/2
60
Armor
Vinyl tape
Sheath
Clamp here
6
100
30
Terminal lug
Содержание FCV-1900/B/G