2. WIRING
8
3. Unfasten four binding screws
to detach the filter cover from
the power terminal.
4. Unfasten and remove the seal
nut from the power cable’s su-
per-gland, then remove the
gasket and fixture from the su-
per-gland.
5. Pass the cable end through
the seal nut, fixture and gasket
in order, then pass the cable
through the super-gland and
into the chassis.
6. Set the gasket assembly onto
the cable. Push the assembly
into the seal nut, then tighten the seal nut.
7. Remove the screws from the power terminal.
8. Check the cable and the terminal polarities, then connect the cable to the terminal.
9. Clamp the cable with the cable clamp.
10. Reattach the filter cover to the power terminal.
11. Fasten the unit cover. When installing an external monitor, continue to the next
step without closing the cover.
2.2.2
External monitor
The external monitor should have 1028 x 1024 (SXGA), 1024 x 1028 (SXGA portrait
type) or 1024 x 768 (XGA) resolution. As the output video signal is HDMI, a HDMI
compatible monitor is required.
Note:
The processor unit FCV-1901 outputs a vertical synchronous video signal of 70
Hz to XGA monitors.
Binding screws (4 pcs.)
Super
gland
(CN-1)
Filter cover
Super-gland
Seal nut
Gasket assembly
Cable clamp
Power terminal
Содержание FCV-1900/B/G
Страница 46: ...D 1 14 Apr 2015 H MAKI...
Страница 47: ...D 2 15 Apr 2015 H MAKI...
Страница 48: ...D 3 15 Jan 2015 H MAKI...
Страница 50: ......
Страница 51: ......