4.6 Using the System Settings Menus
fi-6010N Network Scanner Operator's Guide
79
4
3. Set the area for multifeed detection in the "Multifeed Detection" section.
Starting from the top edge of a document sheet, set the area to be checked for multifeeds.
Full
Multifeeds will be detected within 17.5mm from either side of the cen-
ter of paper.
Middle
Multifeeds will be detected within "#1" (upper limit) and "#2" (lower
limit) set. (a)
Top & Bot-
tom
Multifeeds will be detected from the top of the page to "#1" (upper
limit), and from #2 (lower limit) to the bottom of the page. (b)
Center of paper
(a)
#1
#2
Up to 510mm
Outside of multifeed
detection area
17.5mm
17.5mm
Center of paper
(b)
#1
#2
(b)
Up to 510mm
Outside of multifeed
detection area
17.5mm
17.5mm