Operating Manual
TX2550 M5
Important information
Before starting up
●
During installation and before operating the server, observe the instructions
on environmental conditions for your server.
●
If the server is brought in from a cold environment, condensation may form
both inside and on the outside of the server.
Wait until the server has acclimatized to room temperature and is absolutely
dry before starting it up. Material damage may be caused to the server if this
requirement is not observed.
●
Only transport the server in its original packaging or in packaging that
protects it from impacts and jolts.
In Japan and APAC, transporting the server in its original packaging does
not apply.
Installation and operation
●
This server should not be operated in ambient temperatures above 35 °C.
For servers with Advanced Thermal Design the ambient temperature can
increase to 40 °C or 45 °C.
●
If the server is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
●
The server automatically adjusts itself to a mains voltage, see the type label
of your server. Ensure that the local mains voltage lies within these limits.
●
This server must only be connected to properly grounded power outlets or
connected to the grounded rack internal power distribution server with
tested and approved power cords.
●
Ensure that the server is connected to a properly grounded power outlet
close to the server.
●
Ensure that the power sockets on the server and the properly grounded
power outlets are easily accessible.
●
The On/Off button or the main power switch (if present) does not isolate the
server from the mains power supply. In case of repair or servicing disconnect
the server completely from the mains power supply, unplug all power plugs
from the properly grounded power outlets.
Содержание PRIMERGY TX2550 M5
Страница 1: ...Operating Manual English FUJITSU Server PRIMERGY TX2550 M5 Operating Manual May 2019 ...
Страница 6: ...Operating Manual TX2550 M5 ...
Страница 10: ...Operating Manual TX2550 M5 Content ...
Страница 12: ...12 Operating Manual TX2550 M5 Introduction ...
Страница 16: ...16 Operating Manual TX2550 M5 Before you start ...
Страница 42: ...42 Operating Manual TX2550 M5 Product description ...
Страница 56: ...56 Operating Manual TX2550 M5 Important information ...
Страница 96: ...96 Operating Manual TX2550 M5 Troubleshooting and tips ...
Страница 106: ...106 Operating Manual TX2550 M5 Warranty and service ...