TX2550 M5
Operating Manual
57
5
Starting up
V
CAUTION!
●
Follow the safety instructions in chapter
.
●
Do not expose the server to extreme environmental conditions (see
"Ambient conditions" on page 101
). Protect the server from dust,
humidity and heat.
●
Ensure that the server is acclimatized for the time indicated in this
table before putting it into operation.
In the
, the temperature difference refers
to the difference between the operating environment temperature and
the temperature to which the server was exposed previously (outside,
transport or storage temperature).
Temperature difference (°C)
Minimum acclimatization time
(hours)
5
3
10
5
15
7
20
8
25
9
30
10
Table 3: Acclimatization time