TX2550 M5
Operating Manual
31
Product description
2
[CSS]
CSS
indicator
off
No critical event detected (CSS
component).
orange
on
Prefailure event detected (CSS
component).
For HDDs/SSDs, see also
"HDD/SSD prefailure detection" on
page 33
.
flashing
orange
CSS component failure detected.
3
Global
Error
indicator,
see also
"iRMC-
related
status
signals" on
page 38
off
No critical event detected (non CSS
component).
orange
on
Prefailure event detected (non CSS
component).
flashing
orange
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
4
HDD/SSD
activity
indicator
flashing
green
Data access in progress.
5
Power-on
indicator
off
The server is switched off.
green on
– The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
– The server is switched on and
operating normally.
flashing
green
slowly
The BMC firmware is starting up after
the server has been connected to the
mains.
Pos. Label
Indicator
Status
Description
!
Содержание PRIMERGY TX2550 M5
Страница 1: ...Operating Manual English FUJITSU Server PRIMERGY TX2550 M5 Operating Manual May 2019 ...
Страница 6: ...Operating Manual TX2550 M5 ...
Страница 10: ...Operating Manual TX2550 M5 Content ...
Страница 12: ...12 Operating Manual TX2550 M5 Introduction ...
Страница 16: ...16 Operating Manual TX2550 M5 Before you start ...
Страница 42: ...42 Operating Manual TX2550 M5 Product description ...
Страница 56: ...56 Operating Manual TX2550 M5 Important information ...
Страница 96: ...96 Operating Manual TX2550 M5 Troubleshooting and tips ...
Страница 106: ...106 Operating Manual TX2550 M5 Warranty and service ...