6-2. Outdoor unit
¢
Discharge temperature thermistor
Temperature (°C)
Resistance (kΩ)
Voltage (V)
-30.0
1,013.11
0.06
-25.0
729.09
0.09
-20.0
531.56
0.12
-15.0
392.31
0.16
-10.0
292.91
0.21
-5.0
221.09
0.28
0.0
168.60
0.36
5.0
129.84
0.46
10.0
100.91
0.57
15.0
79.12
0.71
20.0
62.55
0.86
25.0
49.84
1.03
30.0
40.01
1.23
35.0
32.35
1.43
40.0
26.34
1.65
45.0
21.58
1.88
50.0
17.79
2.11
55.0
14.75
2.34
60.0
12.30
2.57
65.0
10.32
2.79
70.0
8.70
3.00
75.0
7.36
3.19
80.0
6.27
3.37
85.0
5.36
3.54
90.0
4.60
3.69
95.0
3.96
3.83
100.0
3.43
3.96
105.0
2.98
4.07
110.0
2.60
4.17
115.0
2.27
4.26
120.0
2.00
4.33
6-2. Outdoor unit
- (03-56) -
6. Thermistor resistance values
TROUBLESHOOTING
TROUBLESHOOTING
Содержание General ASHG07KPCE
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Страница 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Страница 34: ......
Страница 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Страница 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...