STEP 2: Selecting the function number and setting value
1. Press the TEMP./SELECT ( ) ( ) buttons to select the function
number. To switch between the left and right digits, press the MODE
button.
2. Press the FAN SPEED button to proceed the setting value. To re-
turn the function number selection, press the FAN SPEED button
again.
3. Press the TEMP./SELECT ( ) ( ) buttons to select the setting val-
ue. To switch between the left and right digits, press the MODE but-
ton.
4. Press the TIMER button, and
/
(START/STOP) button, in the or-
der listed to confirm the settings.
5. Press the RESET button to cancel the function setting mode.
6. After completing the function setting, be sure to disconnect the pow-
er supply and then reconnect it.
Function number
Setting value
CAUTION
After disconnecting the power supply, wait 30 seconds or more before reconnecting it. The function
setting will not become active unless the power supply is disconnected and then reconnected.
1-1. Function settings by using remote controller
- (05-2) -
1. Function settings
FIELD
WORKING
FIELD
WORKING
Содержание General ASHG07KPCE
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Страница 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Страница 34: ......
Страница 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Страница 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...