4-5. E: 18. Wireless LAN adapter non-energized
Indicator
Indoor unit
Operation indicator
1 time flash
Timer indicator
8 time flash
Economy indicator
Continuous flash
Error code
E: 18
Wireless LAN
adapter
LED1 (green)
Off
LED2 (orange)
Off
Detective actuator
Indoor unit controller PCB
When the voltage (DC 12 V) does not output from the
controller PCB.
Wireless LAN adapter PCB
Forecast of cause
Indoor unit controller PCB failure
Wireless LAN adapter PCB failure
Wiring connection failure
Check point 1. Check the connection.
•
Check any loose or removed connection of between the wireless LAN adapter PCB and con-
troller PCB.
-> If there is abnormal condition, correct it.
•
Check the connection condition on the controller PCB.
-> If there is loose connector, open cable or mis-wiring, correct it.
↓
Check point 2. Check the wireless LAN adapter PCB and the controller PCB
Check voltage at CN12 (terminal 1—2) of main PCB.
(Power supply to remote controller)
•
If it is DC 0 V, controller PCB is failure.
-> Replace controller PCB.
•
If it is DC 12 V, wireless LAN adapter PCB is failure.
-> Replace the wireless LAN adapter and cancel the registration of air condi-
tioner on the mobile app.
After replacing the adapter, perform the pairing on the mobile app.
For the method of the mobile app, refer to
↓
End
4-5. E: 18. Wireless LAN adapter non-energized
- (03-41) -
4. Troubleshooting with error code (For wireless LAN adapter)
TROUBLESHOOTING
TROUBLESHOOTING
Содержание General ASHG07KPCE
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Страница 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Страница 34: ......
Страница 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Страница 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...