1. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE:
Incorrect settings can cause a product malfunction.
1-1. Function settings by using remote controller
Some function settings can be changed on the remote controller. After confirming the setting proce-
dure and the content of each function setting, select appropriate functions for your installation envi-
ronment.
¢
Setting procedure by using wireless remote controller
The function number and the associated setting value are displayed on the LCD of the remote con-
troller. Follow the instructions written in the local setup procedure supplied with the remote controller,
and select appropriate setting according to the installation environment.
Before connecting the power supply of the indoor unit, reconfirm following items:
• Piping air tight test and vacuuming have been performed firmly.
• There is no wiring mistake.
Then, connect the power supply of the indoor unit.
Entering function setting mode:
While pressing the FAN SPEED button and TEMP./SELECT ( ) button simultaneously, press the
RESET button to enter the function setting mode.
STEP 1: Setting the remote controller custom code
Use the following steps to select the custom code of the remote controller. (The signal is correctly
sent and received only when the custom codes of the air conditioner and the remote controller
match.)
The custom codes that are set through this process are applicable only to the signal in the function
setting.
For details on how to set the custom codes through the normal process, refer to
ting for wireless remote controller"
1. Press the TEMP./SELECT ( ) ( ) buttons to change the custom
code between → → → . Match the code on the display to the
air conditioner custom code. (Initially set to .) If the custom code
does not need to be selected, press the MODE button, and proceed
to
STEP 2
.
2. Press the MODE button to accept the custom code, and proceed to
STEP 2
.
NOTES:
• The air conditioner custom code is set to prior to shipment.
• The remote controller resets to custom code when the batteries on the remote controller are
replaced. If you use a custom code other than code , reset the custom code after replacing the
batteries.
• If you do not know the air conditioner custom code setting, try each of the custom codes ( →
→ → ) until you find the code that operates the air conditioner.
1-1. Function settings by using remote controller
- (05-1) -
1. Function settings
FIELD
WORKING
FIELD
WORKING
Содержание General ASHG07KPCE
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Страница 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Страница 34: ......
Страница 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Страница 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...