1-2. Outdoor unit
Type
Inverter heat pump
Model name
AOTG30KMTC
AOTG34KMTC
Power supply
240 V ~ 50 Hz
Available voltage range
198—264 V
Starting current
A
10.7
11.2
Fan
Airflow rate
Cooling
l/s (m
3
/h)
861 (3,100)
1,139 (4,100)
Heating
945 (3,400)
1,139 (4,100)
Type × Q'ty
Propeller fan × 1
Motor output
W
100
111
Sound pressure level *1
Cooling
dB (A)
50
50
Heating
54
54
Sound power level
dB (A)
67
67
Heat exchanger
Dimensions
(H × W × D)
mm
798 × 900 × 36.4
Main1: 882 × 957 × 18.19
Main2: 882 × 927 × 18.19
Sub: 882 × 580 × 18.19
Fin pitch
1.30
1.45
Rows × Stages
2 × 38
Main: 2 × 42, Sub: 1 × 42
Pipe type
Copper
Fin type
Type (Material)
Corrugate (Aluminum)
Surface treatment
Corrosion resistance (Blue fin)
Compressor
Type × Q'ty
DC Twin rotary × 1
Motor output
W
2,200
Refrigerant
Type
R32
Charge
g
1,650
2,000
Refrigerant oil
Type
POE
Amount
cm
3
800
Enclosure
Material
Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
mm
830 × 900 × 330
914 × 970 × 370
Gross
1,000 × 1,050 × 445
1,078 × 1,064 × 479
Weight
Net
kg
60
74
Gross
68
83
Connection pipe
Size
Liquid
mm
Ø 9.52 (Ø 3/8)
Gas
Ø 15.88 (Ø 5/8)
Method
Flare
Pre-charge length
m
20
30
Max. length
75
Max. height difference
30
Operation range
Cooling
°C
-10 to 46
Heating
-15 to 24
Drain hose
Material
LDPE
Size
mm
Ø 13.0 (I. D.), Ø 16.0 to Ø 16.7 (O. D.)
International protection rating
IPX4
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 7.5 m, Height difference: 0 m.
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
1-1. Indoor unit
- (01-2) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Содержание AOTG30KMTC
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2019 06 27 SR_CH01_AS004EF_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 05 12 SR_CH02_AS004EF_05 ...
Страница 35: ...3 TROUBLESHOOTING 2020 05 08 SR_CH03_AS004EF_02 ...
Страница 38: ......
Страница 128: ...6 2 Outdoor unit 03 90 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 129: ...4 CONTROL AND FUNCTIONS 2020 05 08 SR_CH04_AS004EF_02 ...
Страница 132: ......
Страница 163: ...5 FILED WORKING 2019 07 24 SR_CH05_AS004EF_01 ...