4. External input and output (For outdoor unit: AOTG34KMTC
only)
With using external input and output functions, this product can be operated inter-connectedly with
an external device.
Connector
Input
Output
Remarks
CN10
Low noise mode
—
See external input/output settings
for details.
CN11
Peak cut mode
—
CN12
—
Error status
CN13
—
Compressor status
4-1. External input
With using external input function, on/off status of “Low noise mode” and “Peak cut mode” can be
specified by the external signal.
¢
Low noise mode
In following condition, the operating noise of the outdoor unit reduces comparing from the one in nor-
mal operating condition:
The air conditioner is set to the “Low noise mode” when closing the contact input of a commercial
timer or on/off switch to a connector on the control PCB of the outdoor unit.
NOTE:
Product performance may drop depending on some conditions such as the outdoor temper-
ature.
•
Circuit diagram example
Outdoor unit
control PCB
Connected unit
Example: Switch
Connector
1
2
Signal
Locally purchased
*10 m
•
Contact capacity: DC 24 V or more, 10 mA or more.
•
*: Make the distance from the PCB to the connected
unit within 10 m.
•
Construct a circuit as shown in this figure with using
optional parts mentioned below.
•
Input signal: On in “Low noise mode”
•
Input signal: Off in normal operation
•
To set the level of “Low noise mode”, refer to
On
Off
On
Off
Input signal
Low noise mode
•
Optional part
Part name
Model name
Exterior
External connect kit
UTY-XWZXZ3
External input wire
4-1. External input
- (05-32) -
4. External input and output (For outdoor unit: AOTG34KMTC only)
FIELD
WORKING
FIELD
WORKING
Содержание AOTG30KMTC
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2019 06 27 SR_CH01_AS004EF_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 05 12 SR_CH02_AS004EF_05 ...
Страница 35: ...3 TROUBLESHOOTING 2020 05 08 SR_CH03_AS004EF_02 ...
Страница 38: ......
Страница 128: ...6 2 Outdoor unit 03 90 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 129: ...4 CONTROL AND FUNCTIONS 2020 05 08 SR_CH04_AS004EF_02 ...
Страница 132: ......
Страница 163: ...5 FILED WORKING 2019 07 24 SR_CH05_AS004EF_01 ...