Auxiliary heater control 1
Operation
Condition
Heater on
Heater is on as shown in following diagram of heating temperature.
Heater off
•
Heater is off as shown in following diagram of heating temperature.
•
Other than heating mode
•
Error occurred
•
Forced thermostat off
•
Fan stop protection
• Temperature of heater on (Thon): Adjustable by function number 62 (Operating temperature
switching of external heaters).
• All control temperatures will shift by adjusting “Thon”.
Off
Off
On
Tr-Ts ≥ -1°C
Tr-Ts
Tr-Ts (=Thon) < -3°C
Tr-Ts ≥ -10°C
Tr-Ts < -12°C
Tr: Room temperature
Ts: Set temperature
Thon: Heater on temperature
Example:
When set temperature (Ts) is 22°C (Factory setting),
• and room temperature (Tr) increases above 12°C, signal output is on.
• and room temperature (Tr) increases above 21°C, signal output is off.
• and room temperature (Tr) decreases below 19°C, signal output is on.
• and room temperature (Tr) decreases below 10°C, signal output is off.
Auxiliary heater control 2
Operation
Condition
Heater on
Heater is on as shown in following diagram of heating temperature.
Heater off
•
Heater is off as shown in following diagram of heating temperature.
•
Other than heating mode
•
Error occurred
•
Forced thermostat off
•
Fan stop protection
• Temperature of heater on (Thon): Adjustable by function number 62 (Operating temperature
switching of external heaters).
• All control temperatures will shift by adjusting “Thon”.
Off
On
Tr-Ts ≥ -1°C
Tr-Ts
Tr-Ts (=Thon) < -3°C
Tr: Room temperature
Ts: Set temperature
Thon: Heater on temperature
3-4. Details of function
- (05-26) -
3. External input and output (For indoor unit)
FIELD
WORKING
FIELD
WORKING
Содержание AOTG30KMTC
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2019 06 27 SR_CH01_AS004EF_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 05 12 SR_CH02_AS004EF_05 ...
Страница 35: ...3 TROUBLESHOOTING 2020 05 08 SR_CH03_AS004EF_02 ...
Страница 38: ......
Страница 128: ...6 2 Outdoor unit 03 90 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 129: ...4 CONTROL AND FUNCTIONS 2020 05 08 SR_CH04_AS004EF_02 ...
Страница 132: ......
Страница 163: ...5 FILED WORKING 2019 07 24 SR_CH05_AS004EF_01 ...