U41169-J-Z156-4-74
23
Operating and Indicator Elements
Indicator Elements on the Front
V
CAUTION!
The PRIMERGY SX30 storage subsystem does not switch OFF
automatically in the case of overheating. Instead, the server switches it
OFF because data can only be saved to the hard disk drives when the
connected server has been shut down properly. Sudden switching OFF
can destroy the data.
Optical Waveguide
Color
Meaning
Power supply status
none
No mains voltage present.
green
POWER OK
Equipment switched on, all installed power
supply units OK.
yellow
POWER WARNING
One power supply unit has failed.
orange
STANDBY
Equipment switched OFF, mains voltage
present.
Cooling status
green
Cooling OK
All installed fans and the interior temper-
ature are OK.
yellow
Fan warning
One fan has failed.
The temperature is OK.
orange
Cooling fault
All the fans have failed or the interior
temperature exceeds the permissible
values.
Server management
status
none
No meaning.
orange
Identification display
Can be activated manually from
ServerView.
Table 2: Meaning of the Status Indication