Chapter 9 Operation and Maintenance
IRQ not configured
The IRQ settings of the onboard device or the expansion card
are not set. Check and revise the settings on the BIOS Setup
Utility. If the message still appears, replace the expansion card.
If the message still appears, contact an office listed in the
"Contact Information" of "Start Guide".
Expansion ROM not initialized
A PCI expansion ROM initialization error has occurred. Check
the expansion cards or the devices displayed as initialized on the
screen, and replace the failed card. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Allocation error static node #
The onboard device or expansion card cannot be used. Replace
the device or expansion card. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Baseboard Management Controller has
detected an error
A baseboard error has occurred. Check the error log and replace
the relevant option.
iRMC reports sensor status: CRITICAL temp
A temperature error has occurred. Check the system
environment. If the message still appears, it is necessary to the
error log and replace the components in the relevant section.
Contact an office listed in the "Contact Information" of "Start
Guide".
iRMC reports sensor status: WARNING temp
iRMC reports sensor status: CRITICAL
Voltages
A voltage error has occurred. Turn the server off and unplug the
power cable from the outlet. Turn the server back on. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: CRITICAL
Battery
Voltage of the battery is abnormal. Turn the server off and
unplug the power cable from the outlet. Turn the server back on.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
iRMC reports sensor status: WARNING
Battery
iRMC reports sensor status: CRITICAL FAN1
SYS
A system fan error has occurred. Check for hooked objects that
hinders system fan rotation. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
iRMC reports sensor status: CRITICAL FANx
PSU
A PSU fan error has occurred. Check for hooked objects that
hinders PSU fan rotation. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
table: List of POST Error Messages
Message
Contents