Diskette drive A error
A floppy drive error has occurred. Check the set value on the
"8.2.2 Main Menu" (
pg.208) of the BIOS Setup Utility. Check
to see whether the floppy disk drive cable is connected properly.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Incorrect Drive A type - run SETUP
CPU runtime error (IERR#) detected
An installed CPU error has occurred. Check the system event
logs. If the message still appears, contact an office listed in the
"Contact Information" of "Start Guide".
Uncorrectable memory error
A memory error has occurred. Check the error log and replace
the defective memory module (
Modules" (pg.181)). If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Memory configuration has changed - Run
SETUP
A memory error has occurred. Memory size has been changed
since the previous startup. Check the error log and replace the
defective memory module (
"7.3 Installing Memory Modules"
(pg.181)). If the message still appears, contact an office listed in
the "Contact Information" of "Start Guide".
No usable system memory.
A memory error has occurred. No memory is available in the
system. Check the error log and replace the defective memory
module (
"7.3 Installing Memory Modules" (pg.181)). If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
After the replacement, activate the memory in BIOS setup.
Memory module failed! This module is no
longer available for the operating system.
A memory error has occurred. Turn the server off and check that
the memory modules are installed properly. If the message
appears even after the server is turned on again, check the error
log and replace the memory modules (
Modules" (pg.181)). If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
No usable CPU
A CPU error has occurred. Contact an office listed in the
"Contact Information" of "Start Guide".
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
Check that the correct CPUs are installed. If so, update the
BIOS. If the message appears again, change [Reset
Configuration Data] on the "8.2.5 Advanced Menu" (
to [Yes] in the BIOS Setup Utility. If the message still appears,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
CPU disable! CPU is no longer available for
the operating system.
A CPU error has occurred. Contact an office listed in the
"Contact Information" of "Start Guide".
Invalid System Configuration Data
A system configuration error has occurred. Change [Reset
Configuration Data] on "8.2.5 Advanced Menu" (
[Yes] in the BIOS Setup Utility. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Resource Conflict
System resources (IRQs, DMA channels, and I/O port
addresses) conflict between an onboard device and an expansion
card.
Review the system resource settings in the BIOS Setup Utility.
If the message still appears, contact an office listed in the
"Contact Information" of "Start Guide".
table: List of POST Error Messages