3.4Troubleshooting by Error code
DX100 Service Manual
155A
Decompression pump
motor overload error
The electric current flowing when driving the motor is irregularly
large.
• Decompression Pump Unit cable is damaged.
• Irregular load
• Decompression Pump Unit encoder failure
• Decompression Pump Unit failure
1. Check the connection between the Decompression Pump Unit
and Main Board (CN115, CN202).
Replace the Decompression Pump Unit with a
new one.
155B
Decompression pump
motor over speed error
Detects that it is being driven at an irregularly faster speed than the
specified value just before stopping.
• Irregular load
• Encoder failure
• Motor driver failure
---
1. Replace the Decompression Pump Unit
with a new one.
2. Replace the Main Board with a new one.
155C
Decompression pump
motor reversing error
Detects accumulatively more than the specified number of times that
it is being driven in the opposite direction to the specified driving
direction.
• The polarity of Decompression pump motor cable is
opposite.
• Encoder failure
1. Check the connection between the Decompression Pump Unit
and Main Board (CN115, CN202).
Replace the Decompression Pump Unit with a
new one.
155D
Decompression pump
motor driving time-out
error
Detects that the driving period is irregularly long.
• Irregular load
• The firmware has a defect.
---
Replace the Main Board with a new one.
155E
Decompression pump
motor velocity deviation
error
Detects, when accelerating/decelerating the motor, that it is being
driven at an irregularly faster speed than the specified value.
• Irregular load
• Encoder failure
• Motor failure
• Motor driver failure
---
1. Replace the Decompression Pump Unit
with a new one.
2. Replace the Main Board with a new one.
155F
Decompression pump
motor lock error
1. Connection failure of the Decompression pump motor.
2. Detects that it is being driven at an irregularly slower speed than
the specified value.
• Irregular load
• Encoder failure
• Motor failure
1. Check the connection between the Decompression Pump Unit
and Main Board (CN115, CN202).
Replace the Decompression Pump Unit with a
new one.
1801
AID communication
error
An error occurs during AID communication check.
• Connection failure of the AID Board.
• AID Board failure
1. Turn the power off and then on again to check if the printer
recovers from the error.
2. Check the connection between the AID Unit (CN1) and Main
Board (CN101).
3. Carry out “AID Inspection” to check if the AID Unit functions
Replace the AID Unit with a new one.
Table 3-5. Troubleshooting by Error Code
Code
Error Name
Cause
Check Item
Remedy
Содержание Frontier-S DX100
Страница 13: ...13 DX100 Service Manual 7 3 Board Layout Diagram 299 7 4 Board Voltage List 303...
Страница 14: ...C H A P T E R 1 PRODUCTDESCRIPTION...
Страница 29: ...C H A P T E R 2 OPERATINGPRINCIPLES...
Страница 46: ...C H A P T E R 3 TROUBLESHOOTING...
Страница 76: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY...
Страница 208: ...C H A P T E R 5 ADJUSTMENT...
Страница 268: ...268 5 5Paper Feed Related Adjustment DX100 Service Manual 17 Install the Upper Cover P 100 18 Install the Top Cover P 97...
Страница 274: ...274 5 6Ink System Related Adjustment DX100 Service Manual Figure 5 99 Ink Flushing Discharge screen...
Страница 279: ...C H A P T E R 6 MAINTENANCE...
Страница 296: ...C H A P T E R 7 APPENDIX...
Страница 298: ...298 7 2Connector Summary DX100 Service Manual 7 2 Connector Summary PW sensor...
Страница 301: ...301 7 3Board Layout Diagram DX100 Service Manual Heater Board 3 3 V 8 10 5 V_IN 1 2 24 V_A 3 4 F5 24 V_A F6 5 V...
Страница 302: ...302 7 3Board Layout Diagram DX100 Service Manual Power Supply Board...