63
3.4Troubleshooting by Error code
DX100 Service Manual
1412
IS Motor life error
The number of pump operation counter of the Capping Unit reached
the specified upper limit.
---
1. Replace the Capping Unit with a new one.
2. Reset the counter of the Capping Unit.
1432
Passage Pump
maintenance error
Operations of the diaphragm in the Ink Cartridge Holder exceeded
the specified value.
---
1. Replace the Ink Cartridge Holder with a
2. Reset the counter of the Ink Cartridge
Holder.
143D
Driving time-out error
Detects that the driving period of the Capping Unit is irregularly
long.
• Irregular load
• The firmware has a defect.
Check if any foreign objects are stuck in the capping motor.
Check if something is caught at the motor.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Capping Unit with a
1495
Ink leak error
Detects the ink leak in the IES (Ink End Sensor).
Check the ink leak around the Ink Cartridge Holder and the
bottom of that.
Refer to the troubleshooting.
150C
PG origin detection error 1. Connection failure of the APG position sensor.
2. When PG is being adjusted, the APG position sensor cannot
detect its origin.
• APG position sensor failure
• APG Motor failure
3. UR Unit is not moved to the PG adjustment position.
• FFC connection failure
1. Check the connection between the APG position sensor and
Main Board (CN118).
2. Check the attachment status of Head FFC, tubes, and clamps.
Replace the APG Unit with a new one.
1525
Roll motor slacking error Slack Sensor cannot detect a slack when slacking the roll paper
during PF cooperative normal rotation.
• Slack Sensor Unit failure
• Sensor failure
• Sensor cable is damaged.
• Main Board failure
1. Check the connection between the Slack Sensor and Main Board
(CN202).
2. Carry out “Sensor Check” to check if the Slack sensor functions
1. Replace the Slack Sensor Unit with a new
one.
2. Replace the Main Board with a new one.
1529
Oscillation error
The direction of the electric current flowing in the Roll Motor
repeats reversing in the set frequency.
• Motor driver failure
• Encoder failure
• Motor failure
Check if there are any foreign objects (such as a clip) that cause a
short circuit around the motor driver on the board.
Check if the Roll motor Encoder is broken.
Remove the foreign objects on the board if
any.
Error reoccurs
• Replace the Main Board with a new
one.
• Replace the Roll motor with a new
one.
Table 3-5. Troubleshooting by Error Code
Code
Error Name
Cause
Check Item
Remedy
Содержание Frontier-S DX100
Страница 13: ...13 DX100 Service Manual 7 3 Board Layout Diagram 299 7 4 Board Voltage List 303...
Страница 14: ...C H A P T E R 1 PRODUCTDESCRIPTION...
Страница 29: ...C H A P T E R 2 OPERATINGPRINCIPLES...
Страница 46: ...C H A P T E R 3 TROUBLESHOOTING...
Страница 76: ...C H A P T E R 4 DISASSEMBLY ASSEMBLY...
Страница 208: ...C H A P T E R 5 ADJUSTMENT...
Страница 268: ...268 5 5Paper Feed Related Adjustment DX100 Service Manual 17 Install the Upper Cover P 100 18 Install the Top Cover P 97...
Страница 274: ...274 5 6Ink System Related Adjustment DX100 Service Manual Figure 5 99 Ink Flushing Discharge screen...
Страница 279: ...C H A P T E R 6 MAINTENANCE...
Страница 296: ...C H A P T E R 7 APPENDIX...
Страница 298: ...298 7 2Connector Summary DX100 Service Manual 7 2 Connector Summary PW sensor...
Страница 301: ...301 7 3Board Layout Diagram DX100 Service Manual Heater Board 3 3 V 8 10 5 V_IN 1 2 24 V_A 3 4 F5 24 V_A F6 5 V...
Страница 302: ...302 7 3Board Layout Diagram DX100 Service Manual Power Supply Board...