Operator’s Manual: Dura Dry II
MSDS
© SP Industries, Inc.
Rev.004, 12/07
33
========================================================================
Appearance and Odor: PALE YELLOW, VISCOUS LIQUID W/FAINT PETROLEUM ODOR
Boiling Point: >200C
Vapor Pressure (MM Hg/70 F): <0.001
Vapor Density (Air=1): 14
Specific Gravity: 0.87
Solubility In Water: INSOLUBLE
========================================================================
Fire and Explosion Hazard Data
========================================================================
Flash Point: >213C
Flash Point Method: COC
Extinguishing Media: WATER FOG, CHEMICAL FOAM OR CO2
Special Fire Fighting Proc: WEAR BREATHING GEAR WHEN FIGHTING FIRES IN
ENCLOSED SPACES, INCOMPLETE COMBUSTION OF THIS MATERIAL PRODUCES CO.
Unusual Fire And Expl Hazrds: NONE
========================================================================
Reactivity Data
========================================================================Stabil
ity: YES
Cond To Avoid (Stability): CONTINUOUS EXPOSURE TO TEMPERATURES >200C
Materials To Avoid: STRONG OXIDIZERS
Hazardous Decomp Products: INCOMPLETE COMBUSTION MAY PRODUCE CO.
Hazardous Poly Occur: NO
========================================================================
Health Hazard Data
========Route Of Entry - Inhalation: YES
Route Of Entry - Skin: NO
Route Of Entry - Ingestion: YES
Health Haz Acute And Chronic: INHALATION: NAUSEA. EYES: IRRITATION.
DETAILED STUDIES HAVE NOT BEEN MADE, BUT MATERIAL IS NOT EXPECTED TO BE
DERMATITIC OR A SENSITIZER.
Carcinogenicity - NTP: NO
Carcinogenicity - IARC: NO
Carcinogenicity - OSHA: NO
Explanation Carcinogenicity: NONE
Emergency/First Aid Proc: SKIN: WASH W/SOAP & WATER. EYES: FLUSH W/ WATER.
INGESTION: GIVE LIQUIDS & INDUCE VOMITING IF VICTIM IS CONSCIOUS. SMALL
AMOUNTS IN MOUTH MAY BE WASHED OUT. OBTAIN MEDICAL ATTENTION IN ALL CASES.
================================================================
Precautions for Safe Handling and Use
Steps If Matl Released/Spill: SMALL SPILLS: MAY BE WIPED UP W/A RAG. LARGE
SPILLS: SHOULD BE PICKED UP IMMEDIATELY W/AN ABSORBENT.
Waste Disposal Method: PROPER WASTE DISPOSAL PROCEDURES ARE DEPENDENT ON