A–2
A.1.2 Bulk Oil Wiring
TESTING BETWEEN PINS
5
&
8
FIB C
7
SHOULD READ
:
24
VAC WHEN BULK TANK IS FULL
0
VAC WHEN BULK TANK IS NOT FULL
BLACK
24
VAC IN FROM BULK
(HOT
)
WHITE
24
VAC IN FROM BULK
(COM
)
GREEN
24
VAC OUT FRESH OIL PUMP
RED BULK DISPOSE TANK FULL
BULK OIL WIRING
FIB BOX
C
7
12
pin
CONTROL LINE
ADD PUMP
SENSE LINE
WASTE FULL
TESTING BETWEEN PINS
1
&
5
9
-PIN FEMALE PLUG SHOULD READ
:
24
VAC WHEN BULK TANK IS FULL
0
VAC WHEN BULK TANK IS EMPTY
9-
PIN FEMALE
CONNECTION ON REAR OF
FRYER
9-
PIN MALE
CONNECTION ON REAR OF
FRYER
PIN
3
BLACK
24
VAC IN FROM BULK
(HOT
)
PIN
4
YELLOW
24
VAC IN FROM BULK
(COM
)
PIN
2
WHITE
24
VAC OUT FRESH OIL PUMP
PIN
1
RED BULK DISPOSE TANK FULL
PIN
5
BROWN NOT USED
PIN
6
BLUE NOT USED
1
2
3
4
5
6
7
8
9
5
6
7 8
9
10
11
12
4
3
2
1
WARNING
The FilterQuick
™
easyTouch fryer will ONLY operate with bulk oil systems that have a three-
pole float switch. If the float switch is the older two-pole switch, call the bulk oil provider.
These float switches are polarity specific which may short to ground and damage an FIB board.
Содержание FQE60U FilterQuick easyTouch