background image

3–3 

3.2  Operation 

 

This fryer is equipped with FilterQuick

 FQ4000 controller(s) (illustrated below). Refer to the 

FilterQuick 

FQ4000

  Controller  Operation  Manual for

  programming and operating procedures  and for operating 

instructions for the built-in filtration system. 

 

FILTERQUICK

 FQ4000 CONTROLLER 

 

Refer to Chapter 5 of this manual for operating instructions for the built-in filtration system. 
 
3.3   Manual Top-Off, Automatic Top-Off and JIB/Oil Saddle Refill 

 

The fryer can be configured for either 
manual top off or for both manual and 
automatic depending on the hardware.  
When a vat is low, press the manual top off 
(oil  drop) button at the bottom of the 
screen (see Figure 3) to top off the vat. The 
controller displays PUSH BUTTON TOP OFF?  

Press the YES (√) bu

tton.  START FILLING? is 

displayed.  Press and hold the button to 
start filling.  Release the button when the oil 
is at the top oil level line. Press the NO (X) 
button to exit.  If the unit has optional auto 
top off, the frypot oil levels are continually 
checked and topped off as necessary from a 
reservoir in  the cabinet or  the saddle oil 
reservoir  attached to  the cabinet.  The 
reservoir holds a 35-pound box of oil.  In a 
typical operation this will last approximately 
two days before changing. 
Components of the system are annotated at 
the right and below (see Figures 1 and 2). 

 

NOTE:    The top off system is intended to 
top off the frypots, not fill them.  The 
frypots will require manual filling upon 
startup and after disposal  unless a bulk 
fresh system is used.  

Special Cap:  

Has plumbing 

attached to draw oil from the 

reservoir to the fryer vats.

Jug In Box (JIB):  

The JIB is the 

reservoir for the oil.

JIB (Jug In Box) Low 

Reset Switch:  

Resets 

the ATO system after 

oil change.

Figure 1

 

Содержание FQE60U FilterQuick easyTouch

Страница 1: ...isit our website for the latest manual Part Number FRY_IOM_8197624 01 2019 8197624 Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER Keep these instructions for future referen...

Страница 2: ...nitation Manual of the U S Food and Drug Administration WARNING Improper installation adjustment maintenance or service and unauthorized alterations or modifications can cause property damage injury o...

Страница 3: ...it It is designed for a tight fit and should only be removed for cleaning DANGER Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to...

Страница 4: ...nce with the procedures described in this manual Mobile marine or concession conditions of this fryer should be avoided to ensure optimum performance WARNING Do not block the area around the base or u...

Страница 5: ...ust be incorporated in the fixed wiring NOTICE This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply e g a circuit breaker is prov...

Страница 6: ...4 Installing the JIB Cradle 2 4 2 5 Installing the Oil Saddle Reservoir 2 5 CHAPTER 3 Operating Instructions 3 1 Equipment Setup and Shutdown Procedures 3 2 3 2 Operation 3 3 3 3 Manual Top Off Autom...

Страница 7: ...point Accuracy 5 4 5 5 Quarterly Checks and Service 5 4 5 5 1 Replace O rings 5 4 5 6 Annual Periodic System Inspection 5 4 5 6 1 Fryer 5 5 5 6 2 Built In Filtration System 5 5 CHAPTER 6 Operator Trou...

Страница 8: ...ryers 1 2 Safety Information Before attempting to operate your unit read the instructions in this manual thoroughly Throughout this manual you will find notations enclosed in double bordered boxes sim...

Страница 9: ...ssary the user should consult the dealer or an experienced radio and television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Com...

Страница 10: ...with a complete set of service and parts manuals and to stock a minimum amount of parts for Frymaster equipment A list of Frymaster Factory Authorized Servicers FAS s is located on the Frymaster websi...

Страница 11: ...mation about your equipment Most of this information is printed on a data plate affixed to the inside of the fryer door Part numbers are found in the Service and Parts Manual Parts orders may be place...

Страница 12: ...ry supplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer These fryers should be wired to NEC specifications Hardwired units...

Страница 13: ...le material except that it may be installed on combustible floors A clearance of 6 inches 15cm must be provided at both sides and back adjacent to combustible construction A minimum of 24 inches 61cm...

Страница 14: ...60U 22kW 480 3 6 4 11 27 FQE60U 22kW 220 380 4 6 4 11 34 FQE60U 22kW 240 415 4 6 4 11 31 FQE60U 22kW 230 400 4 6 4 11 32 Single Phase Requirements MODEL VOLTAGE WIRE SERVICE MINIMUM WIRE SIZE AWG mm A...

Страница 15: ...appliance without depending on or transmitting stress to the electrical conduit A restraint kit is provided with the fryer If the restraint kit is missing contact your local KES DANGER Hot oil can ca...

Страница 16: ...uick disconnect on the bottom of the reservoir Lift up the orange quick disconnect and insert the male adaptor of the hose Once the male end is fully inserted release the quick disconnect to attach On...

Страница 17: ...el Fuse FilterQuick FQ4000 easyTouch Controller Filter Pan Power Switch Lift Rod JIB Reset Switch Basket Holder Manual Holder Oil Saddle Reservoir Pre Screen Filter Pre Screen Filter Wrench Bulk Dispo...

Страница 18: ...sure that the power is switched on with the master switch located behind the fryer door cabinet on the front panel of the component box next to the fuse 4 Ensure that the controller is switched ON The...

Страница 19: ...ART FILLING is displayed Press and hold the button to start filling Release the button when the oil is at the top oil level line Press the NO X button to exit If the unit has optional auto top off the...

Страница 20: ...eservoir only Remove the Oil Saddle Reservoir lid see Figure 3 and fill with oil Once the reservoir is full ensure the lid is placed over the reservoir Ensure the quick disconnect fitting with hose is...

Страница 21: ...set the top off system see Figure 9 Figure 9 3 3 2 2 Routine Oil Changes Saddle Oil Reservoir only 1 Remove saddle oil reservoir lid 2 Fill the oil saddle with oil 3 Replace saddle oil reservoir lid 4...

Страница 22: ...particularly the aspects of oil filtration draining and cleaning procedures WARNING The filter pad or paper MUST be replaced daily or when the sediment level exceeds the height of the hold down ring...

Страница 23: ...ng it under the drain Figure 2 Figure 3 Figure 4 DO NOT USE FILTER POWDER WITH THE PAD 7 Push the filter pan back into the fryer positioning it under the fryer Ensure P is NOT displayed in the upper r...

Страница 24: ...centration of cleaner and the length of time the cleaner remains on the food contact surfaces 5 2 DAILY CHECKS AND SERVICE 5 2 1 Inspect Fryer and Accessories for Damage Daily Look for loose or frayed...

Страница 25: ...ained from the frypot 2 Use a screwdriver or other similar object which allows access around the probe see Figure 1 Use caution to ensure that the probe is not damaged 3 Return the oil once the clean...

Страница 26: ...To prevent injury ensure adjacent vats that contain oil are OFF and covered prior to performing a Hot Clean Boil Out or Cold Clean Cold Soak 5 4 3 Cleaning the Oil Saddle Reservoir During normal usag...

Страница 27: ...to display the temperature and setpoint of the oil as sensed by the temperature probe 3 Note the temperature on the thermometer or pyrometer Actual temperature and pyrometer readings should be within...

Страница 28: ...rnesses and connections are tight and in good condition 5 6 2 Built In Filtration System Annual Inspect all oil return and drain lines for leaks and verify that all connections are tight Inspect the f...

Страница 29: ...ctive action involves taking steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow find out...

Страница 30: ...as ignored on a prior prompt Change the filter pad and ensure the filter pan has been removed from the fryer for a minimum of 30 seconds Do NOT ignore CHANGE FILTER PAD prompts Fryer does not heat A P...

Страница 31: ...ature measuring circuitry including the probe or damaged controller wiring harness or connector Shut the fryer down and call your FAS for assistance Heating indicator is on but fryer is not heating Th...

Страница 32: ...t to touch for more than a few seconds the thermal overload switch has probably tripped Allow the motor to cool at least 45 minutes then press the Pump Reset Switch see section 2 1 2 of the FQ4000 con...

Страница 33: ...if vat is not filled completely FILLING IN PROGRESS 2 No action required as the pump runs IS VAT FULL 3 Press the check button if the vat is full to continue The controller returns to idle cook mode o...

Страница 34: ...once the vat is full 17 The controller switches off 6 2 3 2 Clogged Drain Error The clogged drain error occurs during auto filtration when the oil level sensor detects that oil has not completely dra...

Страница 35: ...e oil in the top off reservoir is above 70 F 21 C C Ensure the top off reservoir is not out of oil Replace top off reservoir or fill from bulk and reset top off system If problem persists call your FA...

Страница 36: ...M DISCONNECT POWER Vat temperature exceeds 460 F 238 C and the high limit has failed to open Immediately disconnect power to the fryer and call service E19 HEATING FAILURE XXX F or XXX C Heating Contr...

Страница 37: ...e E62 VAT NOT HEATING CHECK ENERGY SOURCE XXXF OR XXXC The vat is not heating properly E63 RATE OF RISE Rate of rise error occurred during a recovery test E64 FILTRATION INTERFACE BOARD FAILURE FILTRA...

Страница 38: ...ryer battery If issue continues contact a FAS E81 SAFE MODE FAILURE ERROR The system has detected the fryer is not heating properly due to low oil conditions Ensure the fryer has oil to the bottom fil...

Страница 39: ...and insert the standard fitting into the jug with the metal cap resting on the lip of the jug The oil is pumped in and out of the jug or saddle reservoirs on singles through the same fitting see Figu...

Страница 40: ...WHEN BULK TANK IS EMPTY 9 PIN FEMALE CONNECTION ON REAR OF FRYER 9 PIN MALE CONNECTION ON REAR OF FRYER PIN 3 BLACK 24VAC IN FROM BULK HOT PIN 4 YELLOW 24VAC IN FROM BULK COM PIN 2 WHITE 24VAC OUT FRE...

Страница 41: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 42: ..._IOM_8197624 01 2019 8197423 WWW WELBILT COM Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge d...

Отзывы: