6-9
Code
ERROR MESSAGE
EXPLANATION
E39
CHANGE FILTER PAD
25-hour timer has expired or dirty filter logic
has activated.
E41
OIL IN PAN ERROR
The system detects that oil may be present in
the filter pan.
E42
CLOGGED DRAIN (Gas)
Vat did not empty during filtration
E43
OIL SENSOR FAILURE - CALL SERVICE
Oil level sensor may have failed.
E44
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E45
RECOVERY FAULT – CALL SERVICE
Recovery time exceeded maximum time limit
for two or more cycles.
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL
SERVICE
SIB board 1 connection lost or board failure.
E51
DUPLICATE BOARD ID - CALL SERVICE
Two or more controllers have the same
location ID.
E52
USER INTERFACE CONTROLLER ERROR - CALL
SERVICE
The controller has an unknown error.
E53
CAN BUS ERROR - CALL SERVICE
Communications are lost between boards.
E54
USB ERROR
USB connection lost during an update.
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL
SERVICE
SIB board 2 connection lost or board failure.
E61
MISCONFIGURED ENERGY TYPE
The fryer is configured for the incorrect
energy type.
E62
VAT NOT HEATING – CHECK ENERGY SOURCE –
XXXF OR XXXC
The vat is not heating properly.
E63
RATE OF RISE
Rate of rise error occurred during a recovery
test.
E64
FILTRATION INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
Filtration Interface Board connections lost or
board failure.
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL
SERVICE
Gas -The oil is back sensor does not detect oil.
Clean oil sensor.
E66
DRAIN VALVE OPEN – XXXF OR XXXC
Drain valve is opened during cooking.
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED -
CALL SERVICE
Controller is turned on when the SIB board is
not configured.
E68
OIB FUSE TRIPPED – CALL SERVICE
The VIB board OIB fuse has tripped and didn’t
reset.
E69
RECIPES NOT AVAILABLE – CALL SERVICE
The controller has not been programmed
with product recipes. Replace controller with
factory programmed controller.
E70
OQS TEMP HIGH
Oil temperature is too high for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
E71
OQS TEMP LOW
Oil temperature is too low for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
E72
TPM RANGE LOW
The TPM is too low for a valid OQS reading.
This may also be seen with fresh new oil. The
incorrect oil type may be selected in the setup