Code
ERROR MESSAGE
EXPLANATION
menu. The sensor may not be calibrated for
the oil type. See oil type chart in instruction
document 8197316. If issue continues
contact a FAS.
E73
TPM RANGE HIGH
The TPM reading is too high for a valid OQS
reading. Dispose the oil.
E74
OQS ERROR
The OQS has an internal error. If issue
continues contact a FAS.
E75
OQS AIR ERROR
The OQS is detecting air in the oil. Check the
O-rings and check/tighten prescreen filter to
ensure no air is entering the OQS sensor. If
issue continues contact a FAS.
E76
OQS ERROR
The OQS sensor has a communication error.
Check connections to the OQS sensor. Power
cycle the entire fryer battery. If issue
continues contact a FAS.
E81
SAFE MODE FAILURE ERROR
The system has detected the fryer is not
heating properly due to low oil conditions.
Ensure the fryer has oil to the bottom fill line
or higher. If not, add oil to the bottom fill
line. If issue continues contact a FAS.
6.2.8 OQS (Oil Quality Sensor) Problems
Problem
Corrective Action
No TPM results
displayed.
Check the following items and perform another OQS filter.
•
Ensure the vat is at setpoint temperature.
•
Inspect the pre-screen filter and ensure it is screwed in tightly.
•
Inspect the O-rings on the filter pan and ensure they are both present
and that they are not missing, cracked or worn. If so replace them.
•
Ensure the filter paper is not clogged and clean filter paper is used.
Did the vat refill the first time for the previous filter? If not change
the filter paper.