6-5
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Semi-automatic
filtration won’t start.
A.
Oil level too low.
B.
Check that MIB board is not in
manual mode.
C.
Check to see that the MIB cover
is not damaged and depressing
the buttons.
D.
Filter relay has failed.
A.
Ensure oil level is above the top oil level
sensor.
B.
Ensure MIB board is in “A” automatic mode.
Power cycle the fryer.
C.
Remove and replace cover and see if filtration
will start.
D.
Call your FAS for assistance.\
Controller displays
OIL SENSOR
FAIL.
Oil sensor may have failed.
Call your FAS for assistance.
Controller
displays
IS VAT
FULL? YES
NO
after a filter
function.
A.
An error has occurred due to
carbon buildup on oil level sensor.
Normal after some filter menu
functions when filling.
B.
All the oil may not have returned
during a filter function due to dirty
or clogged filter paper, clogged
filter pump, filter pump thermal
overload, improperly installed
filter pan components, worn or
missing O-rings, cold oil or an
actuator problem.
A.
If answering yes directs to clean oil sensor,
clean oil level sensor with a scratch pad and
retry. Otherwise press
(YES) if the vat is full,
otherwise press
(NO) and follow prompts.
B.
Check to ensure that the probable causes are
remedied. Follow the prompts to refill the vat.
Controller displays
IS
DRAIN CLEAR?
Drain is clogged and oil failed to
drain.
Clear drain with Fryers Friend and press
YES
button. Filtration will resume.
Controller display
shows
filter
busy
.
Another filtration cycle or filter
paper change is still in process.
Wait until the previous filtration cycle ends to start
another filtration cycle. Change filter paper if
prompted.
6.2.5 Auto Top-Off Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Frypots top off cold.
Incorrect setpoint.
Ensure setpoint is correct.
Frypots won’t top off.
A. Fryer temperature too low.
B. Oil is too cold.
C. JIB out of oil
D. A fryer may be unplugged or
fryer with ATO box may not
have power.
E. Crumb build up around
sensor.
F. Service required error exists
A. Fryer temperature must be at setpoint.
B. Ensure that the oil in the JIB is above 70°F
(21°C).
C. Ensure the JIB is not out of oil and supply
line is in the JIB. Replace JIB and press the
button when prompted and press and
hold the ORANGE reset button for ten (10)
seconds to reset top off system.
If problem persists call your FAS for
assistance.
D.
Check plugs, breakers and
switches.
E. Clean crumbs from opening surrounding
sensor.
F. Call your FAS for assistance.