6-3
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
blower.
your FAS for service.
Controller displays
HEATING
FAILURE
.
Gas valve off, failed controller,
failed transformer, open high-limit
thermostat.
It is normal for this message to appear during
startup if the lines have air in them. Check that
the gas valve is on. If it continues, shut the fryer
down and call your FAS for assistance.
6.2.2 Error Messages and Display Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Controller displays
low temp
.
Frypot temperature has dropped
more than 30°F (17°C) lower than
setpoint in idle mode or 45°F (25°C)
in cook mode.
This display is normal for a short while if a large
batch of frozen product is added to the frypot or if
the fryer is not heating properly. If the issue
persists call your FAS for assistance.
Controller displays
Hot hi-1
.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
Shut the fryer down immediately and call your
FAS for assistance.
Controller displays
Hi
temp.
Frypot temperature is more than 40
ºF (4ºC).
Press the power button to turn off fryer and let
cool before returning power to fryer. If issue
continues call your FAS for assistance.
Controller displays
RECOVERY
FAULT/ YES
and
alarm sounds.
Recovery time exceeded maximum
time limit.
Clear error and silence the alarm by pressing the
(YES) button. Maximum recovery time is 2:25. If
the error continues call your FAS for assistance.
Controller display is in
wrong temperature scale
(Fahrenheit or Celsius).
Incorrect display option
programmed.
Fryers using the FilterQuick
™
controller can toggle
between F° to C° by pressing the
button until
Product setup is displayed. Press
to scroll to
Tech Mode and press
. Enter 1658. Press the
scan button. The controller displays
OFF
. Turn
the controller on to check temperature. If the
desired scale is not displayed, repeat.
Controller displays
High limit
failure
disconnect
power
.
A.
Open drain valve
B.
Failed high limit
A.
Close the drain valve.
B.
Shut the fryer down immediately and call your
FAS for assistance.
Controller displays
TEMP PROBE
FAILURE
Problem with the temperature
measuring circuitry including the
probe or damaged controller wiring
harness or connector.
Shut the fryer down and call your FAS for
assistance.
Controller displays
SERVICE
REQUIRED
followed
by an error message
.
An error has occurred which
requires a service technician.
Press the
(YES) button if the issue is fixed or
press the
(NO) button to continue cooking and
call your FAS for assistance. In some cases,
cooking may not be available.