![Frymaster FilterQuick 5FQG30U Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/frymaster/filterquick-5fqg30u/filterquick-5fqg30u_installation-operation-and-maintenance-manual_2340455044.webp)
6-4
6.2.3 Basket Lift Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Basket lift movement is
jerky and/or noisy.
Basket lift rods need lubrication.
Apply a light coating of Lubriplate
™
or similar
lightweight white grease to the rod and bushings.
6.2.4 Filtration
Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Fryer filters after each
cook cycle.
Filter prompt setting incorrect.
Change the filter prompt setting.
Filter menu functions
won’t start or
controller displays
WAIT FOR
Filter
.
A.
Temperature too low or
controller displays OFF.
B.
Another function is still in
process.
C.
MIB has not cleared checking
system.
D.
Messages or errors on other
controllers.
E.
Filter pan not fully engaged.
A.
Ensure fryer is at setpoint before starting;
ensure the controller is ON.
B.
Wait until the previous function ends to start
another filtration cycle.
C.
Wait one minute and try again.
D.
Clear messages and errors on other controllers.
E.
Ensure the filter pan is in position and fully
inserted into the fryer and “A” is displayed on
the MIB board.
Controller displays
FLT DYLD or
POL dlyd
.
Another function is in process or the
filter has been bypassed.
Wait until the previous function ends to start
another filtration cycle or select “YES” to “FILTER
NOW?” if present on another controller.
Filter pump won’t
start or pump stops
during filtering.
A. Power cord is not plugged in or
circuit breaker is tripped.
B. Pump motor has overheated
causing the thermal overload
switch to trip.
C. Blockage in filter pump.
A. Verify that the power cord is fully plugged in
and the circuit breaker is not tripped.
B. If the motor is too hot to touch for more than a
few seconds, the thermal overload switch has
probably tripped. Allow the motor to cool at
least 45 minutes then press the Pump Reset
Switch (see page 4-3).
C. Call your FAS for assistance.
Filter Pump runs, but
oil return is very slow.
A.
Improperly installed or prepared
filter pan components or cold oil.
A.
Remove the oil from the filter pan and
replace the filter paper, ensuring that the filter
screen is in place
under
the paper.
Verify that O-rings are present and in good
condition on filter pan connection fitting.
Controller displays
OIL IN DRAIN
PAN / CONFIRM
Drain valve open or possibility that
oil is in drain pan.
Press
(CONFIRM) and follow directions for
FILL VAT FROM DRAIN PAN.
Drain valve or return
valve stays open.
A.
AIF board has failed.
B. Actuator has failed.
Call your FAS for assistance.
Controller displays
INSERT pan
.
A.
Filter pan is not fully set into
fryer.
B.
Missing filter pan magnet.
C.
Defective filter pan switch.
A.
Pull filter pan out and fully reinsert into fryer.
B.
Ensure the filter pan magnet is in place and
replace if missing.
C.
If the filter pan magnet is fully against the
switch and computer continues to display
INSERT pan
, switch is possibly defective.
Содержание FilterQuick 5FQG30U