INSTALLATION AND MAINTENANCE MANUAL
TRANSLATION OF THE
ORIGINAL DOCUMENT
For additional copies visit:
www.frost‐trol.com
LOMOND
SOLID LINES
D007918
Versión:
3
-26-
For glass surfaces cleaning, use specific products for it. Water use, will carry on
calcareous deposits. For cleaning the fixed glass, pleas follow the procedure
described in the next section.
4.2.
INTERNAL CLEANING PROCEDURE
To ensure an adequate level of hygiene of your cabinet you must clean and disinfect
the inner parts of the cabinet almost every 30 days. To do so :
-
Remove the cabinet products and put i tonto an adequate cold storage.
-
Apply a defrost.
-
Wait until the inner cabinet parts reach ambient temperature and no frost
rests remain.
Don’t use metallic or cutting objects to accelerate the process. It may
scratch or damage inner surfaces.
-
Clean inner parts with warm water and neutral soap.
-
Dry the surface with a soft cloth.
-
Ensures all the surface are well dried.
-
Close the cabinet doors and switch on the cabinet.
-
Wait until cabinet temperature is correct before loading product inside.
Cleaning procedures never must be made in the presence of products.
Gloves should be worn to protect hands when cleaning inside the
evaporator and the condenser. This will protect hands against possible
cuts or scratches from the unit’s internal elements.
Make sure that the drainage holes are not obstructed by any remaining
merchandise, as this could impede the drainage of excess water resulting
from defrosting.
4.3.
CONDENSER CLEANING PROCEDURE
An inadequate cleaning of condenser will lead to increased energy consumption and
could also cause the compressor break down.
Gloves should be worn to protect hands against cuts or scratches from the
unit’s internal elements.
‐
Unplug the unit from the mains;
‐
Loose the fastening screws and remove the protection grille carefully.