24
35 O
Cut the wire electrode
36
Reserve
37
Reserve
Assignment of
fieldbus connec
-
tion for robot con
-
trol
CAUTION!
Danger of damage to the connection power supply due to overcurrent.
► Provide the power supply with 1.5 A fuse protection against overcurrent.
NOTE!
To avoid interference, keep the line length between the torch body change station
and the robot controller as short as possible.
Arrangement of the bus terminals
I
Input (from the torch body change station to the robot)
A
Output (from the robot to the torch body change station)
Signal
Inputs on bus | terminal
Torch body sensor 1
E01 | terminal 2.2 - 1408
Torch body sensor 2
E02 | terminal 2.2 - 1408
Torch body sensor 3
E03 | terminal 2.2 - 1408
Torch body sensor 4
E04 | terminal 2.2 - 1408
Torch body sensor 5
E05 | terminal 2.2 - 1408
Torch body sensor 6
E06 | terminal 2.2 - 1408
Torch body sensor 7
E07 | terminal 2.2 - 1408
Torch body sensor 8
E08 | terminal 2.2 - 1408
Reserve
E09 | terminal 2.3 - 1408
Reserve
E10 | terminal 2.3 - 1408
Wire sensor signal
E11 | terminal 2.3 - 1408
Swiveling device left
E12 | terminal 2.3 - 1408
Gas nozzle free/"TC ready"
E13 | terminal 2.3 - 1408
Reserve
E14 | terminal 2.3 - 1408
Reserve
E15 | terminal 2.3 - 1408
Parting agent filling level OK
E16 | terminal 2.3 - 1408