Setup menu (2nd) are also not deleted. Exception: Ignition time-out func-
tion parameter (ito).
2nd
Second level of the Setup menu (see "Setup menu - level 2")
Setup paramet-
ers for
MIG/MAG
standard syner-
gic welding
"Min." and "max." are used for setting ranges that differ according to power
source, welding program, etc.
GPr
Gas pre-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
GPo
Gas post-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.5
SL
Slope (special 4-step mode only)
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
I-S
I (current) - Starting - Starting current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 100
I-E
I (current) - End: Final current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 50
t-S
t (time) - Starting - Starting current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
t-E
t (time) - End: Final current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
Fdi
Feeder inching - feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - max. (39.37 - max.)
Factory setting: 10 (393.7)
bbc
Burn-back time correction - burn-back effect
Wire burn-back effect through wire withdrawal at end of welding, regard-
less of the selected characteristic
Unit: s
Setting range: Aut, 0 - 0.3
Factory setting: Aut
95
EN
Содержание TransSteel 3500 Syn
Страница 2: ......
Страница 18: ...18...
Страница 19: ...General information 19...
Страница 20: ...20...
Страница 29: ...Control elements and connections 29...
Страница 30: ...30...
Страница 38: ...38...
Страница 39: ...Installation and commissioning 39...
Страница 40: ...40...
Страница 61: ...Welding 61...
Страница 62: ...62...
Страница 83: ...The arc air gouging parameters are the same as the welding parameters for MMA welding see page 96 83 EN...
Страница 84: ...84...
Страница 85: ...Easy Documentation 85...
Страница 86: ...86...
Страница 91: ...Setup settings 91...
Страница 92: ...92...
Страница 103: ...10 Fit the gas nozzle back onto the welding torch 103 EN...
Страница 105: ...Troubleshooting and maintenance 105...
Страница 106: ...106...
Страница 119: ...Appendix 119...
Страница 120: ...120...
Страница 144: ......