Setting range: 1 - max. (39.37 - max.)
Factory setting: 10 (393.7)
bbc
Burn-back time correction
Burn-back time effect due to a delayed switch-off of the welding current
after the wire electrode stops being fed forward. A ball forms on the wire
electrode.
Unit: s
Setting range: AUt, 0 - 0.3
Factory setting: AUt
IGC
Ignition current
Unit: A
Setting range: 100 - 650
Factory setting: 500
Ito
Length of wire that is fed before the safety cut-out trips
Unit: mm (in.)
Setting range: OFF, 5 - 100 (OFF, 0.2 - 3.94)
Factory setting: OFF
NOTE!
The Ito function (wire length up to safety cut-out) is a safety function.
The length of wire that is fed before the safety cut-out trips may differ from the
pre-set wire length, particularly when the wire is being fed at fast wire speeds.
SPt
Spot welding time / interval welding time
Unit: s
Setting range: 0.3 - 5
Factory setting: 0.3
SPb
Interval pause time
Unit: s
Setting range: OFF, 0.3 - 10 (in 0.1 s increments)
Factory setting: OFF
Int
Interval
Displayed only if a value has been set for SPb
Unit: -
Setting range: 2T (2-step), 4T (4-step)
Factory setting: 2T (2-step)
FAC
Reset power source to factory settings
Press and hold down one of the "Parameter selection" buttons for 2 s to
restore the factory settings
- when "PrG" appears on the digital display, the power source has been re-
set
IMPORTANT!
When the power source is reset, all personal settings in the
Setup menu are lost.
Operating points that were saved using the "Save" buttons are retained
when the power source is reset. The functions in the second level of the
94
Содержание TransSteel 3500 Syn
Страница 2: ......
Страница 18: ...18...
Страница 19: ...General information 19...
Страница 20: ...20...
Страница 29: ...Control elements and connections 29...
Страница 30: ...30...
Страница 38: ...38...
Страница 39: ...Installation and commissioning 39...
Страница 40: ...40...
Страница 61: ...Welding 61...
Страница 62: ...62...
Страница 83: ...The arc air gouging parameters are the same as the welding parameters for MMA welding see page 96 83 EN...
Страница 84: ...84...
Страница 85: ...Easy Documentation 85...
Страница 86: ...86...
Страница 91: ...Setup settings 91...
Страница 92: ...92...
Страница 103: ...10 Fit the gas nozzle back onto the welding torch 103 EN...
Страница 105: ...Troubleshooting and maintenance 105...
Страница 106: ...106...
Страница 119: ...Appendix 119...
Страница 120: ...120...
Страница 144: ......