ASSEMBLY SEQUENCE
12. Check operation of the PROXIMITY SENSOR for bottom/top wrapping and of the zero position
(Fig.1)
Fig 1
13. Check operation of the switches for column/carriage/turntable inverter (Fig.1 / 2 /3)
Fig.1 (Q1) Column Inverter
If you close this switch, power to
the inverter for movement of the
carriage up/down the column is
closed.
Fig.2 (Q2) Carriage Inverter
If you close this switch, power
to the carri
age’s Feed/Brake
(carriage’s right roller) inverter
is closed.
Fig.3 (Q3) Turntable
Inverter
If you close this turntable
switch, power to the
Brake (carriage’s left
roller) inverter is also
closed.