18
Soloclim
GB
Maintenance
Please read data plate to obtain the technical data listed below.
• Power supply voltage
• Maximum absorbed power
• Maximum absorbed current
• Amount of refrigerant gas
• Casing protection level
• Max. working pressure
Reference standards EN 14511. 1. 2.3.4
*) with Dual Power function activated during heating
**) Noise pressure measured 1 m away and 1.5 m high
SC17
SC22
SC21DCI
SC23DCI
Cooling power (1)
kW
1.65
2.30
2.04
2.35
Power in max cooling mod. Dual Power
kW
2.60
3.10
Heating power (2)
kW
1.70
2.25
2.36
2.36
Power in max heating mod. Dual Power
kW
2.64
3.05
Power absorbed when cooling (1)
W
580
850
630
730
Power absorbed when heating (2)
W
545
725
638
720
Dehumidification capacity
l/h
0.8
1.1
1.0
1.1
Power supply voltage:
V-F-Hz
230-1-50
230-1-50
230-1-50
230-1-50
EER
W/W
2.84
2.71
3.24
3.22
COP
W/W
3.12
3.1
3.29
3.28
Energy efficiency ratio when cooling
A
A
A+
A+
Energy efficiency ration when heating
A
A
A
A
Internal-external ventilation speed
No.
3
3
3
3
Dimensions (WxHxD)
mm
1030x555x170
1030x555x170
1030x555x170
1030x555x170
Weight
kg
47.6
48.0
48.5
48.5
Noise level (min-max) **
dB(A)
29/38
32/41
27/41
27/41
Wall holes diameter
mm
162
162
162
162
Wall holes distance
mm
293
293
293
293
Refrigerant gas
R-410A
R-410A
R-410A
R-410A
R410A refrigerant charge
g
480
520
520
520
Maximum absorbed power
W
690
920
1060 *
1060 *
Maximum absorbed current
A
3
4.1
4.8 *
4.8 *
Maximum working pressure PS
MPa
3.8
3.8
3.8
3.8
Degree of protection
IPX0
IPX0
IPX0
IPX0
T ambient
External t
(1)
Cooling mode tests
DB 27°C - WB 19°C
DB 35°C - WB 24°C
(2)
Heating mode tests
DB 20°C - WB 15°C
DB 7°C - WB 6°C
Internal ambient temp.
Outside ambient temp.
Maximum operating temperature in cooling mode
DB 35°C - WB 24°C
DB 43°C - WB 32°C
Minimum operating temperature in cooling mode
DB 18°C
DB -5°C
Maximum operating temperatures in heating
DB 27°C
DB 24°C - WB 18°C
Minimum operating temperatures in heating
DB 5°C
DB -10°C
Technical specifications
Refer conditions
Operating limits